Example: air traffic controller

Shaft Walls - Firestop CHS

Carolinas HealthCare System Shaft Walls Submittal Package STI Contacts: Eric Lacroix T: 704-236-7047 E: elcaroix@stifirestop.com Jay Guidotti T: 704-787-0422

Tags:

  Wall, Submittal, Shaft, Shaft walls, Shaft walls submittal

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Text of Shaft Walls - Firestop CHS

Carolinas HealthCare SystemShaft WallsSubmittal PackageSTI Contacts:Eric LacroixT: 704-236-7047E: GuidottiT: 704-787-0422E: Technologies Inc. | 210 Evans Way | Somerville, NJ 08876 USA | T: | Ratings - 1 and 2 Hr (See Items 2 and 3B)Joint Width- 1 in. MaxL Rating At Ambient - Less Than 1 CFM/Lin Ft (See Item 3B)L Rating At 400 F - Less Than 1 CFM/Lin Ft (See Item 3B)Class II Movement Capabilities-25 Percent Compression or Extension1. Floor Assembly - Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3 )structural Shaft Wall Assembly - With the exception of the ceiling runner, the 1 or 2 hr fire rated shaft wall assembly shall be constructedof the materials and in the manner described in the individual U400 or V400-Series Wall and Partition Design in the UL FireResistance Directory. The wall shall include the following construction features:A. Floor and Wall Runners - (Not Shown) - "J"-shaped runner, min 2-1/2 in. (64 mm) wide with unequal legs of 1 in. (25 mm)and 2 in. (51 mm), fabricated from min 24 MSG galv steel. Runners positioned with short leg toward finished side of attached to walls and floor with steel fasteners spaced max 24 in. (610 mm) OC. As an alternate to the "J"-shapedrunner, a min 2-1/2 in. (64 mm) wide by 1 or 1-1/4 in. (25 or 32 mm) deep channel formed from min 24 MSG galv steel maybe used for the floor Light Gauge Framing* - Slotted Ceiling Track - Slotted ceiling track shall consist of galv steel channels with slottedflanges. Slotted ceiling track sized to accommodate steel "C-H" studs (Items 2C). Attached to concrete at ceiling with steelfasteners spaced max 12 in. OC (305 mm).BRADY CONSTRUCTION INNOVATIONS INC,DBA SLIPTRACK SYSTEMS - SLP-TRKCALIFORNIA EXPANDED METAL PRODUCTS CO - CSTCLARKWESTERN BUILDING SYSTEMS INC - Type SLT, SLT-HMARINO/WARE, DIV OF WARE INDUSTRIESINC - Type SLTSCAFCO STEEL STUD MANUFACTURING COSTEELER INC - Steeler Slotted Ceiling RunnerTELLING INDUSTRIES L L C - True-Action Deflection TrackTHE STEEL NETWORK INC - VertiTrack VT, series,250VT, 362VT, 400VT, 600VT and 800VTR Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 24, 201112 76HWD !~ AN &8+x HW-D-01942B2C3B3A2C2B2D3B2B2C2D3B2C2B2E2 D2E2E11C. Steel Studs - "C-H"-shaped steel studs to be min 2-1/2 in. (64 mm) wide and formed of min 24 MSG galv steel. Studs cut1/2 to 3/4 in. (13 to 19 mm) less in length than assembly height with bottom nesting in and resting on floor runner and withtop nesting in slotted ceiling track. Studs spaced 24 in. (610 mm) OC. After installation of gypsum board liner panels (Item2D), studs secured to flange of floor runner on finished side of wall only with No. 6 by 1/2 in. (13 mm) long self-drilling,self-tapping steel screws. Studs secured to flange of slotted ceiling track on finished side of wall only with No. 8 by 1/2 in.(13 mm) long self-drilling, self-tapping wafer head steel screws at slot Gypsum Board* - 1 in. (25 mm) thick by 24 in. (610 mm) wide gypsum board liner panels as specified in the individualU400 or V400-Series Wall and Partition Design. Panels cut 1 in. (25 mm) less in length than floor to ceiling height. Verticaledges inserted in "H"-shaped section of "C-H" studs. Free edge of end panels attached to long leg of "J" runner (Item 2A)with 1-5/8 in. (41 mm) long Type S steel screws spaced max 12 in. (305 mm) Gypsum Board* - Gypsum board sheets, 1/2 or 5/8 in. (13 or 16 mm) thick, applied vertically or horizontally in one or twolayers on finished side of wall as specified in the individual U400 or V400-Series Wall and Partition Design. A max 1 in. (25mm) gap shall be maintained between the top of the gypsum board and the bottom surface of the concrete floor. Thescrews attaching the gypsum board layers to the C-H studs shall be located 1 in. (25 mm) below the bottom of the slottedceiling track (Item 2C). No gypsum board attachment screws are to penetrate the slotted ceiling hourly fire rating of the joint system is equal to the hourly fire rating of the Joint System - Max separation between bottom of floor and top of liner panel (Item 2D) and between bottom of floor and top ofgypsum board sheets (Item 2E) at time of installation of joint system is 1 in. (25 mm). The joint system is designed toaccommodate a maximum 25 percent compression or extension from its installed width. The joint system consists of bondbreaker tape and sealant, as follows:A. Bond Breaker Tape - Polyethylene tape supplied in rolls. Tape applied to flanges of slotted ceiling track (Item 2D) toprevent bonding of the sealant at points other than the top and bottom of the linear gap. Bond breaker tape is optional whenmovement capability of the joint is limited to compression Fill, Void or Cavity Material* - Sealant - Min 1 in. (25 mm) depth of sealant to be installed to fill linear gap between top ofgypsum board liner panel (Item 2D) and top inside surface of slotted ceiling track (Item 2B) prior to installation of gypsumboard sheets on finished side of wall. For 1 hr fire rated walls, min 5/8 in. (16 mm) depth of sealant to be installed to filllinear gap between top of gypsum board sheet (Item 2E) and bottom of concrete floor. For 2 hr walls, min 1 in. (25 mm)depth of sealant to be installed to fill linear gap between top of gypsum board sheets (Item 2E) and bottom of concrete TECHNOLOGIES INC - SpecSeal ES Elastomeric Sealant or SpecSeal LCI Sealant. L Ratings apply whenSpecSeal ES Elastomeric Sealant is used. When SpecSeal LCI Sealant is used, the movement capability of the jointis limited to 25 percent in compression only.*Bearing the UL Classification MarkR Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 24, 201122HW-D-01941. Floor Assembly - The fire-rated fluted steel deck/concrete floor assembly shall be constructed of the materials and in themanner described in the individual D900 Series Floor-Ceiling Design in the UL Fire Resistance Directory. The hourly firerating of the floor assembly shall be equal to or greater than the hourly fire rating of the wall assembly. The floor assemblyshall include the following construction features:A. Steel Floor and Form Units* - Max 3 in. (76 mm) deep galv steel fluted floor Concrete - Min 2-1/2 in. (64 mm) thick reinforced concrete, as measured from the top plane of the floor units. Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 11, 201115 73HWD %P AO !+-S HW-D-0548System No. HW-D-0548ANSI/UL2079Assembly Ratings - 1 and 2 Hr (See Item 2)Maximum Joint Width - 3/4, 1 or 1-1/2 In. (See Item 3)Class II Movement Capabilities - 50 or 100 %Compression orExtension (See Item 3)L Rating At Ambient - Less Than 1 CFM/sq ftL Rating At 400 F - Less Than 1 CFM/sq ftCAN/ULC S115F Ratings - 1 and 2 Hr (See Item 2)FT Ratings - 1 and 2 Hr (See Item 2)FH Ratings - 1 and 2 Hr (See Item 2)FTH Ratings - 1 and 2 Hr (See Item 2)Maximum Joint Width - 19, 25 or 38 mm (See Item 3)Class II Movement Capabilities - 50 or 100 % Compression orExtension (See Item 3)L Rating At Ambient - Less Than 1 CFM/sq ftL Rating At 400 F - Less Than 1 CFM/sq ft1A. Roof Assembly - (Not Shown) - As an alternate to the floor assembly (Item 1), a fire rated fluted steel deck roof assemblymay be used. The roof assembly shall be constructed of the materials and in the manner described in the individual P900Series Roof-Ceiling Design in the UL Fire Resistance Directory. The hourly fire rating of the roof assembly shall be equal toor greater than the hourly fire rating of the wall assembly. The roof assembly shall include the following constructionfeatures:A. Steel Roof Deck - Max 3 in. (76 mm) deep galv steel fluted roof Roof Insulation - Min 2-1/4 in. (57 mm) thick poured insulating concrete, as measured from the top plane of the steelroof Floor Assembly - As an alternate to the floor assembly (Item 1), min 4-1/2 in. (114 mm) thick reinforced lightweight ornormal weight (100-150 pcf or 1600-2400 kg/m3) structural concrete. Floor may also be constructed of any UL Classifiedhollow-core Precast Concrete Units*.See Precast Concrete Units (CFTV) in Fire Resistance Directory for names of Shaft Wall Assembly - The 1 or 2 hr fire rated shaft wall assembly shall be constructed of the materials and in the mannerdescribed in the individual U400, V400 or W400 Series Wall and Partition Design in the UL Fire Resistance Directory andshall include the following construction features:A. Floor and Ceiling Runners - "J"-shaped runner, min 2-1/2 in. (64 mm) wide with unequal legs of min 1-1/2 in. (38mm) and min 2 in. (51 mm), fabricated from min 24 MSG galv steel. Runners positioned with short leg toward finishedside of wall. Flange height of ceiling runner shall be min 1/4 in. (6 mm) greater than max extended joint attached to walls and floor with steel fasteners spaced max 24 in. (610 mm) OC. As an alternate to the"J"-shaped runner, a min 2-1/2 in. (64 mm) wide by 1 in. or 1 1/4 in. (25 or 32 mm) deep channel formed from min 24MSG galv steel may be used for the floor runner. Ceiling runner installed parallel with or perpendicular to direction offluted steel deck and secured to steel deck valley withy steel fasteners or welds spaced max 24 in. (610 mm) Floor And Ceiling Runners - As an alternate to Item 2A, floor and ceiling runners of wall assembly shall consist ofgalv steel channels sized to accommodate steel "C-H" studs. Flange height of ceiling runner shall be min 1/2 in. (13mm) greater than nom joint width. Ceiling runner installed parallel with or perpendicular to direction of fluted steel deckand secured with steel masonry anchors or welds spaced max 24 in. (610 mm) Light Gauge Framing* - Slotted Ceiling Track - (for use in Configuration A Only) As an alternate to Item 2A,slotted ceiling track shall consist of galv steel channels with slotted flanges. Slotted ceiling track sized toaccommodate steel "C-H" studs (Item 2C). Attached to concrete at ceiling with steel fasteners spaced max 12 in. OC(305 mm).BRADY CONSTRUCTION INNOVATIONS INC, DBA SLIPTRACK SYSTEMS - SLP-TRK, SLPTRK325CALIFORNIA EXPANDED METAL PRODUCTS CO - CSTCLARKDIETRICH BUILDING SYSTEMS - Type SLT, SLT-HMARINO/WARE, DIV OF WARE INDUSTRIES INC - Type SLTSCAFCO STEEL STUD MANUFACTURING COTELLING INDUSTRIES L L C - True-Action Deflection TrackTHE STEEL NETWORK INC - VertiTrack VT, series,250VT, 362VT, 400VT, 600VT and 800VTA3. Light Gauge Framing* - Slotted Ceiling Runner - As an alternate to the ceiling runner in Items 2A through 2A3,slotted ceiling runner to consist of galv steel channel with 3-1/4 in. (83 mm) high slotted flanges sized to accommodatesteel studs (Item 2B). Ceiling runner installed parallel or perpendicular with direction of fluted steel deck and securedto steel deck valley with steel fasteners or welds spaced max 24 in. (610 mm) CONSTRUCTION INNOVATIONS INC, DBA SLIPTRACK SYSTEMS - SLPTRK325B. Steel Studs - "C-H"-shaped steel studs to be min 2-1/2 in. (64 mm) wide and formed of min 24 MSG galv steel. Forconfiguration A studs cut 1/2 to 1-1/4 in. (13 to 32 mm) less in length than assembly height or for configuration B studscut 1 to 1-1/2 in. (25 to 38 mm) less in length than assembly height with bottom nesting in and resting on floor runnerand with top nesting in ceiling runner or slotted ceiling track. Studs spaced 24 in. (610 mm) OC. After installation ofgypsum board liner panels (Item 2D), studs secured to flange of floor runner on finished side of wall with No. 6 by 1/2in. (13 mm) long self-drilling, self-tapping steel screws. Studs secured to flange of slotted ceiling track on finished sideof wall only with No. 8 by 1/2 in. (13 mm) long self-drilling, self-tapping wafer head steel screws at slot midheight. Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 11, 201125HW-D-0548C. Gypsum Board* - 1 in. (25 mm) thick by 24 in. (610 mm) wide gypsum board liner panels. Panels cut 1 in. (25 mm)less in length than floor to ceiling height. Vertical edges inserted in "H"-shaped section of "C-H" studs. Free edge ofend panels attached to long leg of "J" runner (Item 2A) with 1-5/8 in. (41 mm) long Type S steel screws spaced max12 in. (305 mm) Gypsum Board* - Gypsum board sheets, 1/2 or 5/8 in. (13 or 16 mm) thick, applied vertically or horizontally in one ortwo layers on finished side of wall as specified in the individual U400 or V400-Series Wall and Partition Design. A max1 in. (25 mm) gap shall be maintained between the top of the gypsum board and the bottom surface of the concretefloor. The screws attaching the gypsum board layers to the C-H studs shall be located 1 in. (25 mm) below the bottomof the slotted ceiling track (Item 2C). No gypsum board attachment screws are to penetrate the slotted ceiling hourly fire rating of the joint system is equal to the hourly fire rating of the A3. Joint System - Max separation between bottom of floor and top of liner panel (Item 2C) and between bottom offloor and top of gypsum board sheets (Item 2D) at time of installation of joint system 1-1/2 in. (38 mm). The jointsystem is designed to accommodate a maximum 50 percent compression or extension from its installed joint system consists of forming material and sealant, as follows:A. Forming Material* - In floor or roof assembly constructed with steel fluted floor units, compression-fit a minimum 1 in.(25 mm) depth of nom 4 pcf (64 kg/m3) mineral wool batt insulation into far recess of flute valley as a permanent of mineral wool batt insulation cut to width of gypsum liner panel (Item 2C) and compressed 50 percent inthickness. Strip installed between top of gypsum liner panel and bottom of steel ceiling MINWOOL L L C - MinWool 1200 SafingROCK WOOL MANUFACTURING CO - Delta BoardROCKWOOL MALAYSIA SDN BHD - SAFEROXUL INC - SAFETHERMAFIBER INC - SAFB. Fill, Void or Cavity Material*- Sealant - Min 1/8 in. ( mm) wet thickness (min 1/16 in. or mm dry thickness) ofspray applied to cover mineral wool batt insulation within joint cavity (when present; Item 3A) and mineral wool battinstalled above gypsum liner panel (Item 2C). Maintain min 1/2 in. (13 mm) overlaps onto surrounding TECHNOLOGIES INC - SpecSeal AS200 Elastomeric SprayC. Forming Material* - Sections of min 4 pcf (64kg/m3) density mineral wool batt insulation cut to fill flute area (whenpresent) flush with interior surface of wall after installation of spray (Item 3B). Strips of mineral wool batt insulation cutto width of gypsum board layers (Item 2D) and compressed 50 percent in thickness. Strips installed above gypsumboard layers on finished side of wall assembly flush with the wall MINWOOL L L C - MinWool 1200 SafingROCK WOOL MANUFACTURING CO - Delta BoardROCKWOOL MALAYSIA SDN BHD - SAFEROXUL INC - SAFETHERMAFIBER INC - SAFD. Fill, Void or Cavity Material*- Sealant - Min 1/8 in. ( mm) wet thickness (min 1/16 in. or mm dry thickness) ofspray applied to cover mineral wool batt insulation on finished side of wall. Maintain min 1/2 in. (13 mm) overlaps ontosurrounding TECHNOLOGIES INC - SpecSeal AS200 Elastomeric SprayConfiguration B3. Joint System - Max separation between bottom of floor and top of liner panel (Item 2C) and between bottom offloor and top of gypsum board sheets (Item 2D) at time of installation of joint system is 1-1/2 in. (38 mm). The jointsystem is designed to accommodate a maximum 50 percent compression or extension from its installed joint system consists of forming material and sealant, as follows: Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 11, 201135HW-D-0548A. Forming Material* - Strips of min 4 pcf (64kg/m3) density mineral wool batt insulation cut to width of gypsum linerpanel (Item 2C) and compressed 50 percent in thickness. Strip installed between top of gypsum liner panel andbottom of steel ceiling MINWOOL L L C - MinWool 1200 SafingROCK WOOL MANUFACTURING CO - Delta BoardROCKWOOL MALAYSIA SDN BHD - SAFEROXUL INC - SAFETHERMAFIBER INC - SAFB. Fill, Void or Cavity Material*- Sealant - Min 1/8 in. ( mm) wet thickness (min 1/16 in. mm dry thickness) ofspray applied to cover mineral wool batt insulation within joint cavity. Maintain min 1/2 in. (13 mm) overlaps ontosurrounding TECHNOLOGIES INC - SpecSeal AS200 Elastomeric SprayC. Forming Material* - Strips of min 4 pcf (64kg/m3) density mineral wool batt insulation cut to width of gypsum boardlayers (Item 2D) and compressed 50 percent in thickness. Strips installed above gypsum board layers on finished sideof wall assembly flush with the wall MINWOOL L L C - MinWool 1200 SafingROCK WOOL MANUFACTURING CO - Delta BoardROCKWOOL MALAYSIA SDN BHD - SAFEROXUL INC - SAFETHERMAFIBER INC - SAFD. Fill, Void or Cavity Material*- Sealant - Min 1/8 in. ( mm) wet thickness (min 1/16 in. or mm dry thickness) ofspray applied to cover mineral wool batt insulation on finished side of wall. Maintain min 1/2 in. (13 mm) overlaps ontosurrounding TECHNOLOGIES INC - SpecSeal AS200 Elastomeric SprayConfiguration C3. Joint System - Max separation between bottom of floor and top of liner panel (Item 2C) and between bottom offloor and top of gypsum board sheets (Item 2D) at time of installation of joint system is 3/4 or 1 in. (19 or 25 mm).The joint system is designed to accommodate a maximum 100 percent compression or extension for 3/4 in. (19mm) wide joints and a maximum 100 percent compression only for 1 in. (25 mm) wide joints, from its installedwidth. The joint system consists of the following:A. Forming Material* - Nom 3/16 in. ( mm) thick by 4 in. (102 mm) high joint forming material profile installed on bothsides of the wall assembly. Profile installed on the shaft side of the wall by first marking a line across the top of thewall 3 in. (76 mm) below the bottom plane of the bottom of the "J" or ceiling runner on the interior surface of thegypsum liner. Joint profile material on shaft side positioned with its top edge against both the underside of the ceilingrunner with its bottom edge on the line scribed on the shaft liner. Profile installed on the finished side of the wall byfirst marking a line across the top of the wall 3 in. (76 mm) below the bottom plane of the steel floor or roof deckvalleys. Joint profile material on finished side positioned with its top edge against both the underside of the floor orsteel deck with its bottom edge on the line scribed on the finished side of the wall assembly. Bottom of the joint profileattached to gypsum board with nom 1/2 in. (13 mm) long steel staples spaced not greater than 8 in. (203 mm) lengths of profile to overlap approx 3/4 in. (19 mm) at shiplapped TECHNOLOGIES INC - SpecSeal Speed Flex Joint ProfileB. Fill, Void or Cavity Material*- Sealant - Min 1/8 in. ( mm) wet thickness (min 1/16 in. mm dry thickness) ofspray applied to cover forming material within joint cavity (Item 3A) and forming material installed above gypsum linerpanel (Item 2D). Maintain min 1/2 in. (13 mm) overlaps onto surrounding TECHNOLOGIES INC - SpecSeal AS200 Elastomeric Spray Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 11, 201145HW-D-0548C. Forming Material* - Sections of min 4 pcf (64kg/m3) density mineral wool batt insulation cut to fill flute area (whenpresent) flush with interior surface of wall after installation of spray (Item 3B). Strips of mineral wool batt insulation cutto width of gypsum board layers (Item 2E) and compressed 50 percent in thickness. Strips installed above gypsumboard layers on finished side of wall assembly flush with the wall MINWOOL L L C - MinWool 1200 SafingROCK WOOL MANUFACTURING CO - Delta BoardROCKWOOL MALAYSIA SDN BHD - SAFEROXUL INC - SAFETHERMAFIBER INC - SAFD. Fill, Void or Cavity Material*- Sealant - Min 1/8 in. ( mm) wet thickness (min 1/16 in. or mm dry thickness) ofspray applied to cover forming material (Item 3C) on finished side of wall. Maintain min 1/2 in. (13 mm) overlaps ontosurrounding TECHNOLOGIES INC - SpecSeal AS200 Elastomeric Spray*Bearing the UL Classification Mark Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 11, 201155HW-D-0548 Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 11, 201114 78HWD &J AO !+-4 HW-D-0642System No. HW-D-0642ANSI/UL2079Assembly Ratings - 1 and 2 Hr (See Item 1)Nominal Joint Width - 3/4 or 1-1/2 In. (See Item 3)Class II Movement Capabilities - 50% or 100% Compression orExtension (See Item 3)L Rating At Ambient - Less Than 1 CFM/sq ftL Rating At 400 F - Less Than 1 CFM/sq ftCAN/ULC S115F Ratings - 1 and 2 Hr (See Item 1)FT Ratings - 1 and 2 Hr (See Item 1)FH Ratings - 1 and 2 Hr (See Item 1)FTH Ratings - 1 and 2 Hr (See Item 1)Nominal Joint Width - 3/4 or 1-1/2 In. (See Item 3)Class II Movement Capabilities - 50% or 100% Compression orExtension (See Item 3)L Rating At Ambient - Less Than 1 CFM/sq ftL Rating At 400 F - Less Than 1 CFM/sq ftASection A-A2E3B3A3A3B2C2B1D1B1A1C1C2A2B2B2E1DA2D 2ACONFIGURATION A3A1. Floor Assembly - The fire-rated fluted steel deck/concrete floor assembly shall be constructed of the materials and in themanner described in the individual D700, D800, or D900 Series Floor-Ceiling Design in the UL Fire Resistance Directory andshall include the following construction features:A. Steel Floor And Floor Units* - Max 3 in. (76 mm) deep galv steel fluted floor Concrete - Min 2-1/2 in. (64 mm) thick reinforced concrete, as measured from the top plane of the floor Structural Steel Support - Steel beam, as specified in the individual D700, D800, or D900 Series Floor-Ceiling Design,used to support steel floor units. Steel beam centered over and parallel with wall Spray-Applied Fire Resistive Material* - After installation of the steel attachment clips (Item 2B), steel floor units andstructural steel support to be sprayed with the min thickness of material specified in the individual D700, D800, or D900Series Design. The flutes of the steel floor units are to be filled with material across the entire top flange of the steel material shall be applied to the web of the steel beam on each side of the wall. For a 1 hr AssemblyRating, the thickness of material applied to each side of the steel beam web shall be 13/16 in. (21 mm). For a 2 hrAssembly Rating, the thickness of material applied to each side of the steel beam web shall be 1-3/8 in. (35 mm).SOUTHWEST FIREPROOFING PRODUCTS CO - Type 5, Type 5GPW R GRACE & CO - CONN - Type MK-6/HYD1. Spray-Applied Fire Resistive Material* - After installation of the steel attachment clips (Item 2B), steel floor units andstructural steel support to be sprayed with the min thickness of material specified in the individual D700, D800, or D900Series Design. The flutes of the steel floor units are to be filled with material across the entire top flange of the steel material shall be applied to the web of the steel beam on each side of the wall. For a 1 hr AssemblyRating, the thickness of material applied to each side of the steel beam web shall be 11/16 in. (18 mm). For a 2 hrAssembly Rating, the thickness of material applied to each side of the steel beam web shall be 1-1/2 in. (38 mm).ISOLATEK INTERNATIONAL - Type 300 or Type II Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 11, 201124HW-D-0642BSection A-A2E3B3A3A3B2C1D1B1A1C1C2A2B2B2E1DBCONF IGURATION B2D3B3A2. Shaft Wall Assembly - The 1 hr or 2 hr fire rated shaft wall assembly shall be constructed of the materials and in the mannerdescribed in the individual U400, V400 or W400 Series Wall and Partition Design in the UL Fire Resistance Directory and shallinclude the following construction features:A. Floor, Wall and Ceiling Runners - "J"-shaped runner, min 2-1/2 in. (64 mm) wide with unequal legs of min 1-1/2 in. (38mm) and min 2 in. (51 mm), fabricated from min 24 MSG galv steel. Runners positioned with short leg toward finished sideof wall. Flange height of ceiling runner shall be min 1/4 in. (6 mm) greater than max extended joint width. Runnersattached to steel attachment clips (Item 2B) with welds or steel fasteners spaced max 24 in. (610 mm) OC. As an alternateto the "J"-shaped runner, a min 2-1/2 in. (64 mm) wide by 1 in. or 1 1/4 in. (25 or 32 mm) deep channel formed from min24 MSG galv steel may be used for the floor Light Gauge Framing* - Slotted Ceiling Track - (Not Shown) - As an alternate to ceiling runner in Item 2A, slotted ceilingtrack shall consist of galv steel channels with slotted flanges. Slotted ceiling track sized to accommodate steel "C-H" studs(Item 2C) and attached to steel attachment clips (Item 2B) with welds or steel fasteners spaced max 24 in. (610 mm) CONSTRUCTION INNOVATIONS INC, DBA SLIPTRACK SYSTEMS - SLP-TRKCALIFORNIA EXPANDED METAL PRODUCTS CO - CSTCLARKDIETRICH BUILDING SYSTEMS - Type SLT, SLT-HSCAFCO STEEL STUD MANUFACTURING COSTEELER INC - Steeler Slotted Ceiling RunnerTELLING INDUSTRIES L L C - True-Action Deflection TrackTHE STEEL NETWORK INC - VertiTrack VT, series,250VT, 362VT, 400VT, 600VT and 800VTB. Steel Attachment Clips - Z-shaped clips formed from 1 in. (25 mm) wide strips of min 20 ga galv steel. Clips to be sizedto extend through the thickness of the spray-applied fire-resistive material on the bottom flange of the steel beam with 2 in.(51 mm) long upper and lower legs. Legs of clips fastened to bottom of beam (prior to application of spray-appliedfire-resistive materials) and top of ceiling runner with steel fasteners or welds. Clips spaced max 24 in. (610 mm) Steel Studs - "C-H"-shaped steel studs to be min 2-1/2 in. (64 mm) wide and formed of min 24 MSG galv steel. Studs cut1/2 to 1-1/4 in. (13 to 32 mm) less in length than assembly height beneath protected beam with bottom nesting in andresting on floor runner and with top nesting in ceiling runner or slotted ceiling track. Studs spaced 24 in. (610 mm) installation of gypsum board liner panels (Item 2D), studs secured to flange of floor runner on finished side of wallwith No. 6 by 1/2 in. (13 mm) long self-drilling, self-tapping steel screws. Studs secured to flange of slotted ceiling track onfinished side of wall only with No. 8 by 1/2 in. (13 mm) long self-drilling, self-tapping wafer head steel screws at Gypsum Board* - 1 in. (25 mm) thick by 24 in. (610 mm) wide gypsum board liner panels. Liner panels cut 1 in. (25 mm)less in length than assembly height beneath protected beam. Vertical edges inserted in "H"-shaped section of "C-H" edge of end panels attached to long leg of "J" runner (Item 2A) with 1-5/8 in. (41 mm) long Type S steel screwsspaced max 12 in. (305 mm) Gypsum Board* - Gypsum board sheets, 1/2 or 5/8 in. (13 or 16 mm) thick, applied vertically or horizontally in one or twolayers on finished side of wall as specified in the individual U400 or V400-Series Wall and Partition Design. A max 3/4 in.(19 mm) gap shall be maintained between the top of the gypsum board and the bottom surface of the protected steelbeam. The screws attaching the gypsum board layers to the C-H studs shall be located 1 in. (25 mm) below the bottom ofthe ceiling runner (Item 2A or 2A1). No gypsum board attachment screws are to penetrate the ceiling A3. Joint System - Max separation between spray applied fire resistive material on bottom of structural support memberand top of gypsum board (Item 2E) at time of installation of joint system is 1-1/2 in. (38 mm). The joint system isdesigned to accommodate a max 50 percent compression or extension from its installed width as measured betweenbottom plane of the protective material on the steel beam and the top of the gypsum board. The joint system shallconsist of forming and fill materials, as follows: Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 11, 201134HW-D-0642A. Forming Material* - Sections of nom 4 pcf (64 kg/m3) mineral wool batt insulation to be compressed 50 percent inthickness and installed cut edge first to completely fill the gap above the top of the liner panels (Item 2D) and the gapabove the top of the gypsum board (Item 2E).IIG MINWOOL L L C - MinWool-1200 SafingROCK WOOL MANUFACTURING CO - Delta BoardROCKWOOL MALAYSIA SDN BHD - SAFEROXUL INC - SAFETHERMAFIBER INC - Type SAFB. Fill, Void or Cavity Material* - Sealant - Min 1/8 in. ( mm) wet thickness or 1/16 in. ( mm) dry thickness of fillmaterial spray applied over the forming material within the stud cavity prior to installing the finished surface gypsum boardand on the finished side of the wall. Fill material to overlap min 1/2 in. (13 mm) onto gypsum board liner panel and ceilingrunner within wall cavity, min 1/2 in. (13 mm) onto the finished surface gypsum board and min 2 in. (51 mm) onto the sprayapplied material (Item 1D) on the steel TECHNOLOGIES INC - SpecSeal AS200 Elastomeric SprayCONFIGURATION B3. Joint System - Max separation between bottom plane of spray-applied fire resistive material on the steel attachmentclip (Item 1D) and the top of the gypsum board is 3/4 in. (19 mm) or 1 in. (25 mm). The joint system is designed toaccommodate a max 100 percent compression or extension from its installed width as measured between bottomplane of the protective material on the steel beam and the top of the gypsum board or max 100 percent compression(only) from its installed width when the joint width is greater than 3/4 in. The joint system consists of the following:A. Forming Material* - Nom 3/16 in. ( mm) thick by 4 in. (102 mm) high joint forming material profile installed within andon the finished side of the wall assembly. Profile installed on the shaft side of the wall by first marking a line across the topof the wall 3 in. (76 mm) below the web of the "J" runner or ceiling runner channel on the interior surface of the gypsumliner. Joint profile material on shaft side positioned with its top edge against the web of the ceiling runner with its bottomedge on the line scribed on the shaft liner. Profile installed on the finished side of the wall by first marking a line across thetop of the wall 3 in. (76 mm) below the bottom plane of the spray-applied fire resistive material. Joint profile material onfinished side positioned with its top edge against the underside of the spray-applied fire resistive material with its bottomedge on the line scribed on the finished side of the wall assembly. Bottom of the joint profile attached to gypsum linerpanel and gypsum board with nom 1/2 in. (13 mm) long steel staples spaced not greater than 8 in. (203 mm) lengths of profile to overlap approx 3/4 in. (19 mm) at shiplapped TECHNOLOGIES INC - SpecSeal Speed Flex Joint ProfileB. Fill, Void or Cavity Material*- Sealant - Min 1/8 in. ( mm) wet thickness (min 1/16 in. or mm dry thickness) ofelastomeric spray applied to cover forming material (Item 3A) within wall cavity and on finished side of wall. Maintain min1/2 in. (13 mm) overlap onto surrounding substrates with min 2 in. (51 mm) overlap onto spray applied fire resistivematerial on finished side of TECHNOLOGIES INC - SpecSeal AS200 Elastomeric Spray*Bearing the UL Classification Mark Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 11, 201144HW-D-0642Assembly Ratings - 1 and 2 Hr (See Item 2)Nominal Joint Width - 1 Rating At Ambient - Less Than 1 CFM/Lin FtL Rating At 400 F - Less Than 1 CFM/Lin FtClass II Movement Capabilities - Compression or Extension1. Floor Assembly - The fire-rated fluted steel deck/concrete floor assembly shall be constructed of the materials and in themanner described in the individual D700 or D800 Series Floor-Ceiling Design in the UL Fire Resistance Directory. The hourlyfire rating of the floor assembly shall be equal to or greater than the hourly fire rating of the wall assembly. The floor assemblyshall include the following construction features:A. Steel Floor And Floor Units* - Max 3 in. (76 mm) deep galv steel fluted floor Concrete - Min 2-1/2 in. (64 mm) thick reinforced concrete, as measured from the top plane of the floor Structural Steel Support - Steel beam or open-web steel joist, as specified in the individual D700 or D800 SeriesFloor-Ceiling Design, used to support steel floor units. Structural steel support oriented parallel to and 1 to 6 in. (25 to 152mm) from wall Steel Lath - When structural steel support (Item 1C) consists of open-web steel joists, 3/8 in. (10 mm) diamond meshexpanded steel lath having a nom weight of to lb per sq yd ( to kg/m2) shall be installed to completely coverone side of each joist which is located within 6 in. (152 mm) of wall assembly. The lath shall be secured with steel tie wireand shall be fully covered with spray applied fire resistive Spray-Applied Fire Resistive Material* - After installation of the ceiling runner (Item 2A or 2A1), steel floor units andstructural steel supports to be sprayed with the thickness of material specified in the individual D700 or D800 SeriesDesign. The flutes of the steel floor units above the structural steel supports and above the ceiling runner (Item 2A or 2A1)shall be filled with spray-applied fire resistive material. As an alternate, the spray-applied fire resistive material in the flutesabove the ceiling runner may be applied to follow the contour of the steel floor INTERNATIONAL - Type 300 or Type IIW R GRACE & CO - CONN - Type MK-6/HY, MK-6/HYES, MK-65 and Roof Assembly - (Not Shown) - As an alternate to the floor assembly (Item 1), a fire rated fluted steel deck roof assemblymay be used. The roof assembly shall be constructed of the materials and in the manner described in the individual P700 orP800 Series Roof-Ceiling Design in the UL Fire Resistance Directory. The hourly fire rating of the roof assembly shall beequal to or greater than the hourly fire rating of the wall assembly. The roof assembly shall include the following constructionfeatures:R Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 11, 201113 77HWD &K AO !+-: HW-D-06433BA3A1C2B2C1B1AASection A-A1D1E3B3B3A3C1B1A2A2DA. Steel Roof Deck - Max 3 in. (76 mm) deep galv steel fluted roof Roof Insulation - Mineral and Fiber Board* - Min 3/4 in. (19 mm) thick boards applied in one or more layers directly oversteel roof deck or over gypsum board sheathing laid atop steel roof Roof Covering* - Hot-mopped or cold-application materials compatible with mineral and fiber board Structural Steel Support - Steel beam or open-web steel joist, as specified in the individual P700 or P800 SeriesRoof-Ceiling Design, used to support steel floor units. Structural steel support oriented parallel to and 1 in. to 6 in. (25 to152 mm) from wall Steel Lath - When structural steel support (Item 1D) consists of open-web steel joists, 3/8 in. (10 mm) diamond meshexpanded steel lath having a nom weight of to lb per sq yd ( to kg/m2) shall be installed to completely coverone side of each joist which is located within 6 in. (152 mm) of wall assembly. The lath shall be secured with steel tie wireand shall be fully covered with spray applied fire resistive Spray-Applied Fire Resistive Material* - After installation of the ceiling runner (Item 2A or 2A1), steel roof deck andstructural steel supports to be sprayed with a thickness of spray applied fire resistive material as specified in the individualP700 or P800 Series Roof-Ceiling design. The flutes of the steel deck above the structural steel supports and above theceiling runner (Item 2A or 2A1) shall be filled with spray-applied fire resistive material. As an alternate, the spray-appliedfire resistive material in the flutes above the ceiling runner may be applied to follow the contour of the steel roof material shall be removed from the flanges of the ceiling runner or deflection track beyond the required thicknessof spray-applied fire resistive material on the steel roof INTERNATIONAL - Type 300 or Type IIW R GRACE & CO - CONN - Type MK-6/HY, MK-6/HYES, MK-65 and Shaft Wall Assembly - The 1 or 2 hr fire rated shaft wall assembly shall be constructed of the materials and in the mannerdescribed in the individual U400 or V400 Series Wall and Partition Design in the UL Fire Resistance Directory. The wall shallinclude the following construction features:A. Floor, Wall and Ceiling Runners - "J"-shaped runner, min 2-1/2 in. (64 mm) wide with unequal legs of 1 in. (25 mm) and2 in. (51 mm), fabricated from min 24 MSG galv steel. Runners positioned with short leg toward finished side of attached to ceiling, walls and floor with steel fasteners spaced max 24 in. (610 mm) OC. As an alternate to the"J"-shaped runner, a min 2-1/2 in. (64 mm) wide by 1 or 1-1/4 in. (25 or 32 mm) deep channel formed from min 24 MSGgalv steel may be used for the floor Steel Studs - "C-H"-shaped steel studs to be min 2-1/2 in. (64 mm) wide and formed of min 24 MSG galv steel. Studs cut1/2 to 3/4 in. (13 to 19 mm) less in length than assembly height with bottom nesting in and resting on floor runner and withtop nesting in ceiling runner. Studs spaced 24 in. (610 mm) OC. After installation of gypsum board liner panels (Item 2D),studs secured to flange of floor runner on finished side of wall only with No. 6 by 1/2 in. (13 mm) long self-drilling,self-tapping steel Gypsum Board* - 1 in. (25 mm) thick by 24 in. (610 mm) wide gypsum board liner panels as specified in the individualU400 or V400 Series Wall and Partition Design. Panels cut 1 in. (25 mm) less in length than floor to ceiling height. Verticaledges inserted in "H"-shaped section of "C-H" studs. Free edge of end panels attached to long leg of "J" wall runner (Item2A) with 1-5/8 in. (41 mm) long Type S steel screws spaced max 12 in. (305 mm) Gypsum Board* - Gypsum board sheets, 1/2 or 5/8 in. (13 or 16 mm) thick, applied vertically or horizontally in one or twolayers on finished side of wall as specified in the individual U400 or V400-Series Wall and Partition Design. A max 1/2 in.(13 mm) gap shall be maintained between the top of the gypsum board and the spray-applied fire resistive material on theunderside of the steel Joint System - Max separation between bottom plane of steel floor unit and top of gypsum board liner panel (Item2D) at time of installation of joint system is 1 in. (25 mm). Max separation between spray applied fire resistivematerial on structural support member and surface of wall is 4 in. (102 mm). The joint system is designed toaccommodate a max percent compression or extension from its installed width as measured between thebottom plane of the steel floor unit and the top of the gypsum board liner panel. The joint system shall consist offorming and fill materials, as follows:R Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 11, 201123HW-D-0643A. Forming Material* - Nom 4 pcf (64 kg/m3) density mineral wool batt insulation. Nom 1 in. (25 mm) wide strips of mineralwool batt insulation compressed min 50 percent in thickness and inserted cut-edge first into gap above top of gypsum linerpanels prior to installation of gypsum board on finished side of wall. Sections of mineral wool batt cut to a width of 4 in.(102 mm) and stacked to attain a thickness which is 50 percent greater than the width of the linear gap between the sprayapplied fire resistive material on the structural steel member and the finished side of the shaft wall assembly. Stackedsections of mineral wool compressed minimum 33 percent in thickness and installed cut edge first into linear gap until thebottom edge is flush with the bottom surface of the spray applied fire resistive material on the structural steel the spray-applied fire resistive material in the flutes above the wall follows the contour of the steel deck, sections ofmineral wool batt cut to the shape of the fluted deck and stacked to a min 6 in. (152 mm) thickness shall be installed in theflutes of the steel floor or roof deck between the top of the ceiling runner and the spray-applied fire resistive material. Themineral wool batt insulation is to be installed flush with the gypsum board surface on the side of the wall opposite thestructural steel MINWOOL L L C - MinWool-1200 SafingROCK WOOL MANUFACTURING CO - Delta BoardROCKWOOL MALAYSIA SDN BHD - SAFEROXUL INC - SAFETHERMAFIBER INC - Type SAFB. Fill, Void or Cavity Material* - Sealant - Min 1/8 in. ( mm) wet thickness or 1/16 in. ( mm) dry thickness of fillmaterial spray applied over the forming material in the linear gap above the gypsum liner panels and on the on theunderside of the forming material between the structural steel support member on the finished side of the wall. Fill materialto overlap a min of 1/2 in. (13 mm) onto the gypsum board and inside of the ceiling runner and a min of 2 in. (51 mm) ontothe spray applied material on the structural steel support TECHNOLOGIES INC - SpecSeal AS200 Elastomeric Spray*Bearing the UL Classification MarkR Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 11, 201133HW-D-06431. Floor Assembly - Min 4-1/2 in. (114 mm) thick steel-reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3)structural concrete. Floor may also be constructed of any min 6 in. thick (152 mm) UL Classified hollow-core Precast ConcreteUnits*.See Precast Concrete Units (CFTV) category in Fire Resistance Directory for names of Wall Assembly - The 1 or 2 hr fire rated gypsum board/steel stud shaft wall assembly shall be constructed of the materials andin the manner specified in the individual U400, V400 or W400 Series Wall and Partition Design in the UL Fire ResistanceDirectory. The wall shall include the following construction features:A. Steel Floor Runner - "J"-shaped runners, min 4 in. (102 mm) deep, with unequal legs of 1 in. (25 mm) and 2 in. (51 mm),fabricated from min 24 MSG galv steel. Runners positioned with short leg toward finished side of wall. Runners attached tostructural supports with steel fasteners located not greater than 2 in. (51 mm) from ends and not greater than 24 in. (610mm) OC. Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 20, 201312 68hwd & #4-o HW-D-0697System No. HW-D-0697ANSI/UL2079Assembly Ratings - 1 and 2 Hr (See Item 2)Nominal Joint Width - 3/4 II or III Movement Capabilities - 100% Compression (SeeItem 3)L Rating at Ambient - Less Than 1 CFM/Lin FtL Rating at 400 F - Less Than 1 CFM/Lin FtCAN/ULC S115F Ratings - 1 and 2 Hr (See Item 2)FT Ratings - 1 and 2 Hr (See Item 2)FH Ratings - 1 and 2 Hr (See Item 2)FTH Ratings - 1 and 2 Hr (See Item 2)Nominal Joint Width - 19 mmClass II or III Movement Capabilities - 100% Compression (SeeItem 3)L Rating at Ambient - Less Than 1 CFM/Lin FtL Rating at 400 F - Less Than 1 CFM/Lin FtSECTION A-A3A2A2C113A2C3B2A3A13A2C3A3B3B2BAAB. Studs - "C-H", "E" (back-to-back), I or "C-T"-shaped studs, min 2-1/2 in. (64 mm) deep, fabricated from min 25 MSG galvsteel. Cut to lengths 3/8 to 1/2 in. (10 to 13 mm) less than floor-to-ceiling height and spaced 24 in. (610 mm) Gypsum Board* - 1 in. (25 mm) thick gypsum liner panels and 1/2 in., 5/8 in. or 3/4 in. (13, 16 or 19 mm) thick gypsumpanels installed as specified in the individual wall designs in the UL Fire Resistance hourly ratings of the joint system are equal to the hourly rating of the Joint System - Max separation between bottom of floor and top of wall is 3/4 in. (19 mm). The joint system consists of thefollowing:A. Fill, Void or Cavity Material* - Factory-supplied intumescent gasket installed over the steel J shaped ceiling runner (Item2A) prior to attachment to bottom of concrete floor. Gypsum liner panel to be installed maintaining a maximum 3/4 in. (19mm) gap between the top of the liner panel and the bottom surface of the ceiling runner. Gypsum wallboard layer(s) to beinstalled on finished side of the wall maintaining a minimum 1/8 in. (3 mm) overlap over the intumescent paper profile attime of TECHNOLOGIES INC - Speed Flex Track Top GasketB. Forming Material* - Nom 4 in. (102 mm) thick by 6 in. (152 mm) wide sections of 4 pcf (64 kg/m3) mineral wool battinsulation installed between studs (Item 2 B) flush with the bottom surface of the steel J shaped floor MINWOOL L L C - MinWool-1200 SafingROCK WOOL MANUFACTURING CO - Delta BoardROCKWOOL MALAYSIA SDN BHD - SafeROXUL INC - SafeTHERMAFIBER INC - SAF*Bearing the UL Classification Mark Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 20, 201322HW-D-06971. Floor Assembly - Min 4-1/2 in. (114 mm) thick steel-reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3)structural concrete. Floor may also be constructed of any min 6 in. thick (152 mm) UL Classified hollow-core Precast ConcreteUnits*.See Precast Concrete Units (CFTV) category in Fire Resistance Directory for names of Wall Assembly - The 1 or 2 hr fire rated gypsum board/steel stud shaft wall assembly shall be constructed of the materials andin the manner specified in the individual U400, V400 orW400 Series Wall and Partition Design in the UL Fire ResistanceDirectory. The wall shall include the following construction features:A. Steel Floor Runner - "J"-shaped runners, min 4 in. (102 mm) deep, with unequal legs of 1 in. (25 mm) and 2 in. (51 mm),fabricated from min 24 MSG galv steel. Runners positioned with short leg toward finished side of wall. Runners attached tostructural supports with steel fasteners located not greater than 2 in. (51 mm) from ends and not greater than 24 in. (610mm) OC. Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 20, 201312 67hwd & #4-u HW-D-0698System No. HW-D-0698ANSI/UL2079Assembly Ratings - 1 and 2 Hr (See Item 2)Nominal Joint Width - 1/2 II or III Movement Capabilities - 100% Compression or 50% Extension (See Item 3)L Rating at Ambient - Less Than 1 CFM/Lin FtL Rating at 400 F - Less Than 1 CFM/Lin FtCAN/ULC S115F Ratings - 1 and 2 Hr (See Item 2)FT Ratings - 1 and 2 Hr (See Item 2)FH Ratings - 1 and 2 Hr (See Item 2)FTH Ratings - 1 and 2 Hr (See Item 2)Nominal Joint Width - 13 mmClass II or III Movement Capabilities - 100% Compression or 50% Extension (See Item 3)L Rating at Ambient - Less Than 1 CFM/Lin FtL Rating at 400 F - Less Than 1 CFM/Lin FtSECTION A-A3A2A2C113A2C3B2A3A13A2C3A3B3B2BAAB. Studs - "C-H", "E" (back-to-back), I or "C-T"-shaped studs, min 2-1/2 in. (64 mm) deep, fabricated from min 25 MSG galvsteel. Cut to lengths 3/8 to 1/2 in. (10 to 13 mm) less than floor-to-ceiling height and spaced 24 in. (610 mm) Gypsum Board* - 1 in. (25 mm) thick gypsum liner panels and 1/2 in., 5/8 in. or 3/4 in. (13, 16 or 19 mm) thick gypsumpanels installed as specified in the individual designs in the UL Fire Resistance hourly ratings of the joint system are equal to the hourly rating of the Joint System - Max separation between bottom of floor and top of wall is 1/2 in. (13 mm). The joint system consists of thefollowing:A. Fill, Void or Cavity Material* - Factory-supplied intumescent gasket installed over the steel J shaped ceiling runner (Item2A) prior to attachment to bottom of concrete floor. Gypsum liner panel to be installed maintaining a maximum 1/2 in. (13mm) gap between the top of the liner panel and the bottom surface of the ceiling runner. Gypsum wallboard layer(s) to beinstalled on finished side of the wall maintaining a minimum 1/8 in. (3 mm) overlap over the intumescent paper profile attime of TECHNOLOGIES INC - Speed Flex Track Top GasketB. Forming Material* - Nom 4 in. (102 mm) thick by 6 in. (152 mm) wide sections of 4 pcf (64 kg/m3) mineral wool battinsulation installed between studs (Item 2 B) flush with the bottom surface of the steel J shaped floor MINWOOL L L C - MinWool-1200 SafingROCK WOOL MANUFACTURING CO - Delta BoardROCKWOOL MALAYSIA SDN BHD - SafeROXUL INC - SafeTHERMAFIBER INC - SAF*Bearing the UL Classification Mark Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 20, 201322HW-D-06981. Wall Assembly - The 1 or 2 hr fire-rated gypsum board/stud shaft wall assembly shall be constructed of the materials and inthe manner specified in the individual U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shallincorporate the following construction features:A. Steel Studs - "C-H" or "C-T" shaped studs, min 2-1/2 in. (64 mm) wide by 1-1/2 in. (38 mm) deep, fabricated from min gauge ( mm thick) galv steel, spaced max 24 in. (610 mm) Gypsum Board* - 1 in. (25 mm) thick, 24 in. (610 mm) wide gypsum liner panels installed vertically. Max diam of circularcutout in gypsum liner panel is 10 in. (254 mm).C. Gypsum Board* - 1/2 in. or 5/8 in. (13 or 16 mm) thick, 48 in. ( m) wide gypsum boards. The gypsum board type,thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and PartitionDesign. Max diam of circular cutout in gypsum board is 10 in. (254 mm).The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it Metallic Sleeve - Cylindrical sleeve fabricated from min No. 30 gauge ( mm thick) galv sheet steel and having a min 2 in.(51 mm) lap along the longitudinal seam. Length of the sleeve to be equal to the thickness of the wall. Sleeve installed bycoiling the sheet steel to a diam smaller than the through opening, inserting the coil through the opening and releasing the coilto let it uncoil against the circular cutouts in the gypsum board layers. The ends of the steel sleeve shall be flush with eachsurface of the Through Penetrant - - One metallic pipe, tube or conduit installed concentrically or eccentrically within the firestop annular space between the pipe, tube or conduit and the periphery of the sleeved opening to be min 0 in. (0 mm, pointcontact) to max 2 in. (51 mm). Pipe, tube or conduit to be rigidly supported on both sides of wall assembly. One of the followingtypes and sizes of pipe, tube or conduit may be used:A. Steel Pipe - Nom 8 in. (203 mm) diam (or smaller) Schedule 5 (or heavier) steel Iron Pipe - Nom 8 in. (203 mm) diam (or smaller) cast or ductile iron Conduit - Nom 4 in. (102 mm) diam (or smaller) rigid steel conduit, steel electrical metallic tubing (EMT) or flexible Copper Pipe or Tube - Nom 4 in. (102 mm) diam (or smaller) Regular (or heavier) copper pipe or Type L (or heavier)copper tube. Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 24, 201112 86WL0 ,S AA (8+2 W-L-1251A21C4B4A1A4A4B2334B1BASystem No. W-L-1251ANSI/UL1479 (ASTM E814)F Ratings - 1 and 2 Hr (See Item 1)T Rating - 0 HrCAN/ULC S115F Ratings - 1 and 2 Hr (See Item 1)FT Rating - 0 HrFH Ratings - 1 and 2 Hr (See Item 1)FTH Rating - 0 Hr4. Firestop System - The firestop system consist of the following items:A. Packing Material - Min 4 pcf (64 kg/m3) mineral wool batt insulation firmly packed into sleeved opening as a permanentform. Packing material to extend throughout thickness of wall except for a 1 in. (25 mm) deep recess on the finished side ofwall to accommodate the fill Fill Void or Cavity Materials* - Sealant or Putty - Min 1 in. (25 mm) thickness of fill material applied within sleeve, flushwith finished surface of wall. At the point contact location, a min 3/8 in. (10 mm) diam bead of fill material shall be applied atthe penetrant/sleeve TECHNOLOGIES INC - SpecSeal Series SSS Sealant, SpecSeal LCI Sealant, or SpecSeal Putty*Bearing the UL Classification Mark Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 24, 201122W-L-1251F Rating - 2 HrT Rating - 2 Hr1. Wall Assembly - The 1 or 2 hr fire-rated gypsum board/stud shaft wall assembly shall be constructed of the materials and inthe manner specified in the individual U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shallincorporate the following construction features:A. Steel Studs - "C-H" or "C-T" shaped studs, min 2-1/2 in. (64 mm) wide by 1-1/2 in. (38 mm) deep, fabricated from min gauge ( mm thick) galv steel, spaced max 24 in. (610 mm) Gypsum Board* - 1 in. (25 mm) thick, 24 in. (610 mm) wide gypsum liner panels installed vertically. Diam of circular cutoutin gypsum liner panel to be equal to outside diam of firestop device (Item 3B).C. Gypsum Board* - 1/2 in. or 5/8 in. (13 to 16 mm) thick, 48 in. ( m) wide gypsum boards. The gypsum board type,thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and PartitionDesign. Diam of circular cutout in gypsum board to be max 1/2 in. (13 mm) larger than diam of through penetrant (Item 2).The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it Through Penetrant - One nonmetallic pipe or conduit installed centered within the firestop system. Pipe or conduit to be rigidlysupported on both sides of wall assembly. One of the following types and sizes of nonmetallic pipe or conduit may be used:A. Polyvinyl Chloride (PVC) Pipe - Nom 4 in. (102 mm) diam (or smaller) Schedule 40 PVC solid or cellular core PVC pipefor use in vented (drain, waste or vent) or closed (process or supply) piping Acrylonitrile Butadiene Styrene (ABS) Pipe - Nom 4 in. (102 mm) diam (or smaller) Schedule 40 ABS solid or cellularcore PVC pipe for use in vented (drain, waste or vent) or closed (process or supply) piping Chlorinated Polyvinyl Chloride (CPVC) Pipe - Nom 4 in. (102 mm) diam (or smaller) SDR17 CPVC pipe for use in vented(drain, waste or vent) or closed (process or supply) piping Rigid Nonmetallic Conduit+ - Nom 4 in. (102 mm) diam (or smaller) Schedule 40 PVC conduit installed in accordance withArticle 347 of the National Electrical Code (NFPA 70).3. Firestop System - The firestop system consist of the following items:A. Fill Void or Cavity Materials* - Sealant or Putty - (Optional) - Min 1/4 in. (6 mm) thickness of fill material applied withinannulus of gypsum board on finished side of TECHNOLOGIES INC - SpecSeal Series SSS Sealant or SpecSeal LCI Sealant or SpecSeal PuttyB. Firestop Device* - Firestop device sized to the specific diam of the through penetrant to be friction fit into circular cutout ingypsum liner panel from the interior of the wall. Diam of circular cutout in gypsum liner panel to be equal to outside diam offirestop device. Device shall be secured to the gypsum liner panel with min 3/16 in. (5 mm) diam steel toggle bolts or mollybolts in conjunction with 1-1/4 in. (32 mm) diam steel fender washers in accordance with the accompanying installationinstructions. Second firestop device sized to the specific diam of the through penetrant installed around the throughpenetrant on the finished side of the wall and secured to the gypsum board with min 3/16 in. (5 mm) diam steel toggle boltsor molly bolts in conjunction with 1-1/4 in. (32 mm) diam steel fender washers in accordance with the accompanyinginstallation TECHNOLOGIES INC - SpecSeal Firestop Collar, SpecSeal LCC Collar or SpecSeal SSC Collar*Bearing the UL Classification MarkR Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 27, 201211 79WL0 6Y AL +;,Q W-L-225721A3A3B1C23B3B1BAA1. Wall Assembly - The 1 or 2 hr fire-rated gypsum board/stud shaft wall assembly shall be constructed of the materials and inthe manner specified in the individual U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shallincorporate the following construction features:A. Steel Studs - "C-H" or "C-T" shaped studs, min 2-1/2 in. (64 mm) wide by 1-1/2 in. (38 mm) deep, fabricated from min gauge ( mm thick) galv steel, spaced max 24 in. (610 mm) Gypsum Board* - 1 in. (25 mm) thick, 24 in. (610 mm) wide gypsum liner panels installed vertically. Max diam of circularcutout in gypsum liner panel is 4 in. (102 mm).C. Gypsum Board* - 1/2 in. or 5/8 in. (13 or 16 mm) thick, 48 in. ( m) wide gypsum boards. The gypsum board type,thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and PartitionDesign. Max diam of circular cutout in gypsum board is 4 in. (102 mm).The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it Metallic Sleeve - Cylindrical sleeve fabricated from min No. 30 gauge ( mm thick) galv sheet steel and having a min 2 in.(51 mm) lap along the longitudinal seam. Length of the sleeve to be equal to the thickness of the wall. Sleeve installed bycoiling the sheet steel to a diam smaller than the through opening, inserting the coil through the opening and releasing the coilto let it uncoil against the circular cutouts in the gypsum board layers. The ends of the steel sleeve shall be flush with eachsurface of the Cables - Aggregate cross-sectional area of cables to be max 51 percent of the cross-sectional area of the opening. Cables tobe tightly bundled. The annular space within the firestop system shall be min 0 in. (point contact) to max 1 in. (0 to 25 mm).Cables to be rigidly supported on both sides of wall assembly. Any combination of the following types and sizes of cables maybe used:A. Max 400 pair No. 24 AWG telephone cable with PVC insulation and Max 1/C - 750 kcmil copper conductor cable with XLPE or PVC insulation and Max 7/C No. 12 AWG with PVC insulation and Max 4 pair No. 24 AWG data cable with PVC insulation and Max RG/U coaxial cable with fluorinate ethylene jacket and insulation. Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 24, 201112 76WL0 ?n AA (8+Y W-L-3178ASection A-A21C4B4A1A4B2331BASystem No. W-L-3178ANSI/UL1479 (ASTM E814)F Ratings - 1 and 2 Hr (See Item 1)T Rating - 1/4 HrCAN/ULC S115F Ratings - 1 and 2 Hr (See Item 1)FT Rating - 1/4 HrFH Ratings - 1 and 2 Hr (See Item 1)FTH Rating - 1/4 HrF. Multiple fiber optic cables jacketed with PVC and having a max OD of 5/8 Max 3/C No. 3/0 aluminum or copper conductor SER cable with PVC insulation and Max 4/C No. 2/0 AWG copper or aluminum conductor steel or aluminum jacketed Metal-Clad# or Armored-Clad# CABLE SYSTEMS INC4. Firestop System - The firestop system consist of the following items:A. Packing Material - Min 4 pcf (64 kg/m3) mineral wool batt insulation firmly packed into sleeved opening as a permanentform. Packing material to extend throughout thickness of wall except for a 1 in. (25 mm) deep recess on the finished side ofwall to accommodate the fill Fill Void or Cavity Materials* - Sealant or Putty - Min 1 in. (25 mm) thickness of fill material applied within sleeve, flushwith finished surface of wall. Fill material forced into grouped cable interstices to max extent possible. At the point contactlocation, a min 1/4 in. (6 mm) diam bead of fill material shall be applied at the cable bundle/sleeve TECHNOLOGIES INC - SpecSeal Series SSS Sealant, SpecSeal LCI Sealant or SpecSeal Putty*Bearing the UL Classification Mark Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 24, 201122W-L-31781. Wall Assembly - The 1 or 2 hr fire-rated gypsum board/stud shaft wall assembly shall be constructed of the materials and inthe manner specified in the individual U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shallincorporate the following construction features:A. Steel Studs - "C-H" or "C-T" shaped studs, min 2-1/2 in. (64 mm) wide by 1-1/2 in. (38 mm) deep, fabricated from min gauge ( mm thick) galv steel, spaced max 24 in. (610 mm) Gypsum Board* - 1 in. (25 mm) thick, 24 in. (610 mm) wide gypsum liner panels installed vertically. Max diam of circularcutout in gypsum liner panel is 8 in. (204 mm).C. Gypsum Board* - 1/2 in. or 5/8 in. (13 or 16 mm) thick, 48 in. ( m) wide gypsum boards. The gypsum board type,thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and PartitionDesign. Max diam of circular cutout in gypsum board is 8 in. (203 mm).The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it Metallic Sleeve - Cylindrical sleeve fabricated from min No. 30 gauge ( mm thick) galv sheet steel and having a min 2 in.(51 mm) lap along the longitudinal seam. Length of the sleeve to be equal to the thickness of the wall. Sleeve installed bycoiling the sheet steel to a diam smaller than the through opening, inserting the coil through the opening and releasing the coilto let it uncoil against the circular cutouts in the gypsum board layers. The ends of the steel sleeve shall be flush with eachsurface of the Steel Duct - One nom 6 in. (152 mm) diam (or smaller) min No. 30 gauge ( mm thick) galv steel vent duct to be installedeither concentrically or eccentrically within the firestop system. The annular space between the vent duct and the periphery ofthe opening shall be min 0 in. (0 mm, point contact) to max 2 in. (51 mm). Steel vent duct to be rigidly supported on both sidesof the wall assembly. Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 24, 201112 76WL0 fb AA (8+< W-L-7066A21C4B4A1A4A4B2331B4BASystem No. W-L-7066ANSI/UL1479 (ASTM E814)F Ratings - 1 and 2 Hr (See Item 1)T Rating - 0 HrCAN/ULC S115F Ratings - 1 and 2 Hr (See Item 1)FT Rating - 0 HrFH Ratings - 1 and 2 Hr (See Item 1)FTH Rating - 0 Hr4. Firestop System - The firestop system consist of the following items:A. Packing Material - Min 4 pcf (64 kg/m3) mineral wool batt insulation firmly packed into sleeved opening as a permanentform. Packing material to extend throughout thickness of wall except for a 1 in. (25 mm) deep recess on the finished side ofwall to accommodate the fill Fill Void or Cavity Materials* - Sealant or Putty - Min 1 in. (25 mm) thickness of fill material applied within sleeve, flushwith finished surface of wall. At the point contact location, a min 3/8 in. (10 mm) diam bead of fill material shall be applied atthe penetrant/sleeve TECHNOLOGIES INC - SpecSeal Series SSS Sealant, SpecSeal LCI Sealant, or SpecSeal Putty*Bearing the UL Classification Mark Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 24, 201122W-L-7066F Ratings - 1 and 2 Hr (See Item 1)T Rating - 0 HrL Rating At Ambient - Less Than 1 CFM/sq ftL Rating At 400 F - Less Than 1 CFM/sq ft1. Wall Assembly - The 1 or 2 hr fire-rated gypsum board/stud shaft wall assembly shall be constructed of the materials and inthe manner specified in the individual U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shallincorporate the following construction features:A. Steel Studs - "C-H" or "C-T" shaped studs, min 2-1/2 in. (64 mm) wide by 1-1/2 in. (38 mm) deep, fabricated from min gauge ( mm thick) galv steel, spaced max 24 in. (610 mm) Gypsum Board* - 1 in. (25 mm) thick, 24 in. (610 mm) wide gypsum liner panels installed vertically. Max area of opening is90 sq in. (581 cm2) with max dimension of 9-1/2 in. (241 mm).C. Gypsum Board* - 1/2 in. or 5/8 in. (13 or 16 mm) thick, 48 in. ( m) wide gypsum boards. The gypsum board type,thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and PartitionDesign. Max area of opening is 90 sq in. (581 cm2) with max dimension of 9-1/2 in. (241 mm).The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it Steel Duct - One nom 8 by 8 in. (203 by 203 mm) (or smaller) min No. 30 gauge ( mm thick) galv steel vent duct to beinstalled either concentrically or eccentrically within the firestop system. The annular space between the vent duct and theperiphery of the opening shall be min 1/2 in. to max 1 in. (13 to 25 mm). Steel vent duct to be rigidly supported on both sides ofthe wall Firestop System - The firestop system consists of the following items:A. Forming Material - Min 4 pcf (64 kg/m3) mineral wool batt insulation compression fit between the gypsum liner panel andthe gypsum board as a permanent form within the stud cavity. Height and width of mineral wool batt forming material to benom 12 by 12 in. (305 by 305 mm) and centered around steel duct. Thickness of batt to be min 10 percent greater than thedepth of the stud cavity to maintain compression between gypsum liner panel and gypsum Fill, Void or Cavity Material* - Sealant - Fill material thickness installed to full depth of gypsum board layers on each sideof wall TECHNOLOGIES INC - SpecSeal Series SSS Sealant, SpecSeal LCI Sealant, SpecSeal LC150 Sealant orSpecSeal LE600 Sealant.*Bearing the UL Classification MarkR Created or Revised:Reproduced courtesy of Underwriters Laboratories, OF(800)992-1180 (908)526-8000 FAX (908)231-8415 24, 200911 79WL0 fz AA $8)I W-L-70903A3B2A3A1B1C1A3B3BACertificate of Conformance Technical Service 1-800-992-1180 Series SSS Intumescent SealantSpecSeal Series LCI Intumescent SealantSpecSeal Series LC Firestop SealantSpecSeal Series ES Elastomeric SealantSpecSeal Series SIL300 Silicone SealantSpecSeal Series SIL300SL Silicone SealantPensil PEN300 Silicone SealantPensil PEN300SL Silicone SealantPensil PEN200 Silicone FoamType WF300 Firestop CaulkSpecSeal Series AS200 Elastomeric SpraySpecSeal Series FT Fast Tack Firestop SpraySpecSeal Series SSP Putty & Putty PadsSpecSeal Series EP PowerShield Box InsertSpecSeal Series SSM Firestop MortarSpecSeal Series SSB Firestop PillowsSpecSeal Series CS Composite SheetSpecSeal Series SSW Wrap StripsSpecSeal Series LCC Firestop CollarsSpecSeal Series SSC Firestop CollarsSpecSeal Series RTC Firestop CollarsSpecSeal Series FP Firestop PlugsSpecSeal Series CD Cast-In Firestop DevicesFyreFlange Firestop AngleEZ-Path Series 22EZ-Path Series 33EZ-Path Series 44 or 44+Ready SleeveReady Sleeve SplitReady Firestop GrommetSpecSeal Series SSAMW Mineral WoolSpecSeal SpeedFlex Fire Rated Joint ProfileDescription: SpecSeal Firestop Products; Pensil Silicone Sealants; EZ-Path Fire Rated Pathways; Ready Sleeve Firestop Sleeves; STI Firestop ProductsIncluded Products:These products are tested to one or more of the following standards: ASTM E814 (ANSI/UL1479) Standard Test Method for Fire Tests of Penetration Firestop Systems ASTM E1966 (ANSI/UL2079) Standard Test Method for Fire-Resistive Joint Systems ASTM E119 (ANSI/UL263) Standard Test Methods for Fire Tests of Building Construction and Materials ASTM E2307 Standard Test Method for Determining Fire Resistance of Perimeter Fire Barrier Systems Using Intermediate Scale, Multi-Story Test Apparatus ASTM E1399 Standard Test Method for Cyclic Movement and Measuring the Minimum and Maximum Joint Widths of Architectural Joint Systems ASTM E84 (ANSI/UL723) Standard Test Method for Surface Burning Characteristics of Building Materials CAN/ULC S115 Standard Method of Fire Tests of Firestop Systems CAN/ULC S101 Standard Methods of Fire Endurance Tests of Building Construction and Materials IMO Resolution (18)Chemical Content Statement:No asbestos, PCB s, lead, or water-soluble intumescent ingredients are used or contained in these M. JankowskiQuality Control ManagerJames P. Stahl Jr., CFPSVice President of EngineeringGENERAL CERTIFICATE OF CONFORMANCEJanuary 25, 20111Technical Service SERIES AS200 ELASTOMERIC SPRAYPRODUCT DATA SHEETAPPLICATIONSSpecSeal Elastomeric Spray is designed primarily for the protection of construction joints, curtain wall safing gaps, and certain DESCRIPTIONSpecSeal Series AS200 Elastomeric Spray is a non-halogenated latex-based, highly elastomeric coating designed to provide passive smoke and fire protection in construction Series AS200 Elastomeric Spray is engineered to adhere to virtually all construction surfaces and may be applied using airless spray equipment or with a brush (ideally for, but not limited to, small applications or touch ups).SpecSeal Series AS200 Elastomeric Spray dries to form a flexible shield against the propagation of fire. Its premium latex binder system is totally resistant to water and will not re-emulsify after drying. SpecSeal Series AS200 Elastomeric Spray contains no inorganic fibers, asbestos, solvents. Water-Based for easy installation and cleanup Non-halogenated. Thixotropic for high-build application. Auto Bonding. no solvents! No asbestos! Flexible! Water Resistant! Low Abrasion for longer pump life and less maintenance. UL Classified. Tested with spray applied fire resistive materials (SFRM). Paintable FEATURES When applied to a wet film thickness of 1/8" ( mm) over appropriate backing materials, SpecSeal Series AS200 Elastomeric Spray has been successfully tested in one, two, three and four hour joints tested in accordance with ASTM E1966 (ANSI/UL2079) and CAN/ULCS115. This product has also been tested for use in Perimeter Fire Barrier Systems in accordance with ASTM E2307. Consult factory for individual system designs and application : Use product as per manufacturer s instructions. Use only in applications per the manufacturer s tested and published designs or specific recommendations. End user must ultimately determine the suitability of the product and designs to his specific requirement and assumes responsibility for its use. PRODUCT CONTAINS WATER AND IS CONDUCTIVE UNTIL DRY. DO NOT APPLY IN THE PRESENCE OF EXPOSED OR ENERGIZED ELECTRICAL CONDUCTORS. PERFORMANCEPHYSICAL PROPERTIESSTI Product Data Sheet Series AS200 Elastomeric Spray FOD-5042-1292PROPERTIES: SERIES AS SPRAYColorPale Blue and RedOdorMild LatexSpecific Content by WeightSolids Content by Volume74% Spread0*Smoke Developed25*Movement 50%** sq ft/gal @ 1/8 ( sq m/L @ mm)Viscosity110,000 : SERIES AS SPRAYSolvent ContentNonePlasticizerNoneIn-Service Temp. 185 F (85 C)Storage F (4 C) - 95 F (35 C)Drying TimeTack Free 2 HoursDry Through 24-48 HoursASTC Rating61VOC ContentB10 g/LShelf Life18 Months* Tested to ASTM E84 (UL723) @ 14% coverage.**500 Cycles per UL2079, AC30 (ICBO) and ASTM E1399A Dependent on temperature and ASTM D3960 EPA Fed. Reference Method 24FILL, VOID OR CAVITY MATERIALS FOR USE IN JOINT SYSTEMS & THROUGHPENETRATION FIRESTOP SYSTEMS. SEE UL FIRE RESISTANCE System Compatible indicates that this product has been tested, and is monitored on an ongoing basis, to assure its chemical compatibility with FlowGuard Gold , BlazeMaster and Corzan pipe and fittings. FBC, FlowGuard Gold, BlazeMaster and Corzan are licensed trademarks of The Lubrizol Service Product Data Sheet Series AS200 Elastomeric Spray FOD-5042-1292FIG. 2: SLAB-EDGE SAFING GAP APPLICATIONSUL System No. CW-S-2061F Rating 2 Hr T Rating 1/4 HrLinear Opening Width - 8 In MaxL Rating At Ambient - Less than 1 CFM/Lin FtL Rating At 400o F - Less Than 1 CFM/Lin FtFIG. 1: METALLIC PIPE PENETRATIONS - CONCRETE/MASONRY FLOORS & WALLSUL System No. C-AJ-1318F Rating 2 Hr T Rating 0 HrSteel or Iron Pipe: <12", Copper Pipe: <6"Annulus: Point Contact to 2"Forming Material: Nom 4 pcf mineral wool to 4" depthSpray Depth: 1/8" wet depth (+1/2" overlap)UL System No. HW-D-0043Assembly Ratings - 1,2,3 and 4 Joint Widths - 1 and 2 Rating At Ambient - Less than 1 CFM/Lin Rating At 400o F - Less Than 1 CFM/Lin II Movement Capabilities - 40 or 50% Compression and 3: HEAD-OF-WALL APPLICATIONS3Technical Service Product Data Sheet Series AS200 Elastomeric Spray FOD-5042-1292AVAILABILITYMAINTENANCEInspection: Installations should be inspected periodically for subsequent damage. Following safety precautions listed below (See Precautionary Information) and pertinent installation guidelines, remove coating in damaged areas down to undamaged material. Reapply fresh coating material to original coating thickness. TECHNICAL SERVICESpecified Technologies Inc. provides toll free technical support to assist in product selection and appropriate installation design. UL Systems, Material Safety Data Sheets and other technical information is available at the Technical Library at INFORMATIONConsult Material Safety Data Sheet for additional information on the safe handling and disposal of this material. Wash areas of skin contact with soap and water. Avoid contact with eyes. The use of an OSHA or NIOSH approved mask for dust and mist environment is recommended. Apply in areas with adequate Series AS200 Elastomeric Spray is available worldwide from authorized distributors. Consult factory for the names and locations of the nearest sales representatives or GENERAL: Areas to be protected must be clean and free of oil, loose dirt, rust or scale. Recommended storage temperatures range between40 F (4 C) and 95 F (35 C). Installation temperature shall be between 40 F (4 C) and 95 F (35 C). Although not a requirement, the optimal application temperature range is 60 F (16 C) to 90 F (32 C). When applying product at the lower end of the temperature range, warming the material to 70 F (21 C) will enhance drying characteristics. Drying time will vary according to prevailing temperature and humidity. Allow to thoroughly dry before exposure to appropriate manufacturer s drawing for system design requirements. Forming or packing materials are required as an integral part of various system may be applied by airless spray in a single pass up to 3/16" ( ) wet coating depth. If applying by brush or spraying on vertical surfaces where coating appears to be prone to slumping, multiple coats or the application of a thin tack coat may be required. DO NOT ATTEMPT TO THIN PRODUCT BY ADDING WATER. When dry, may be painted using most non-solvent based INSTRUCTIONSSPECIFICATIONSThe fire protective joint coating shall be a water-based, non-halogenated elastomeric coating and shall contain no solvents, inorganic fibers, nor asbestos. The coating shall dry to form a flexible, moisture resistant film and shall adhere to all common construction surfaces. The coating shall provide up to 50 percent movement. The coating shall be thixotropic and shall be capable of being applied by brush or by airless spray. The approved coating shall be SpecSeal Series AS200 Elastomeric DIVISIONSDIV. 7 07 84 00 Through-Penetration FirestoppingDIV. 4 04 22 00 Concrete Unit MasonryDIV. 7 07 21 00 Thermal InsulationDIV. 8 08 44 00 Curtain Wall and Glazed Assemblies4Technical Service Product Data Sheet Series AS200 Elast Spray FOD-5042 01/2012Important Notice: All statements, technical information, and recommendations contained herein are based upon testing believed to be reliable, but the accuracy and completeness thereof is not : Specified Technologies Inc. manufactures its goods in a manner to be free of defects. Should any defect occur in its goods (within one year), Specified Technologies Inc., upon prompt notification, will at its option, exchange or repair the goods or refund the purchase and Exclusions: THIS WARRANTY IS IN LIEU OF ALL OTHER REPRESENTATIONS EXPRESSED OR IMPLIED (INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR USE) AND UNDER NO CIRCUMSTANCES SHALL SPECIFIED TECHNOLOGIES INC. BE RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL PROPERTY DAMAGE OR LOSSES. PRIOR TO USE, THE USER SHALL DETERMINE THE SUITABILITY OF THE PRODUCT FOR ITS INTENDED USE, AND THE USER ASSUMES ALL RISKS AND LIABILITY FOR SUBSEQUENT statement or recommendation not contained herein shall have any force or effect unless in an agreement signed by officers of seller and IN THE USA COPYRIGHT 2012 SPECIFIED TECHNOLOGIES INFORMATIONSpecSeal Elastomeric Spray is available in 5 gal. pails, 55 gal. drums are available on a special order Pale Blue Color 5 gal. Pail 1,155 cu. in. (19 liters)AS205R Red Color 5 gal. Pail 1,155 cu. in. (19 liters)CITY OF NEW YORK MEA 310-99-M210 Evans Way, Somerville NJ 08876 USA Phone: Fax: A: APPLICATION EQUIPMENTNOTICE: Spray application of SpecSeal Elastomeric Spray requires airless spray equipment meeting the following specifications:Working Pressure: Min. 2500 PSI (172 Bar)Delivery: Min. .72 gpm ( l/min.) recommendedSpray Tip Orifice: to ( to mm) recommendedWetted Parts All seals and contact surfaces suitable for contact with latex minimum 3/8 ( mm) fluid line is required, a 1/2 (13 mm) line is preferred. Consult pump manufacturer for long hose runs or lifts to higher elevations. A reversible spray tip is recommended. A 6 (152 mm) fan pattern is suggested to minimize following airless spray equipment has demonstrated suitability for application of this product. STI makes no warranties concerning the suitability or use of this equipment and has no affiliation of any kind with its Model Number & DescriptionTitan Tool Inc. 740ix Electric Airless SprayerGraco Inc. Ultra Max II 695 Electric Airless Sprayer SERIES ES ELASTOMERIC SEALANT1Technical Service DESCRIPTIONAPPLICATIONSPERFORMANCE Water-Based for easy installation and cleanup. Non-halogenated. Thixotropic for high-build application. Auto bonding. No solvents! No asbestos! Elastomeric! Water-Resistant! UL Classified. Acoustical sealant Paintable FEATURES PRODUCT DATA SHEETFILL, VOID OR CAVITY MATERIALS CLASSIFIED BY UNDERWRITERS LABORATORIES INC. FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS. SEE UL FIRE RESISTANCE DIRECTORY UNDERWRITERS LABORATORIES INC. CLASSIFIED WALL PROTECTION MATERIAL. SEE PRODUCT CATEGORY IN UL FIRE RESISTANCE DIRECTORYCLASSIFIED FILL, VOID, OR CAVITY MATERIALS FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS. SEE UL DIRECTORY OF PRODUCTS CERTIFIED FOR CANADA AND UL FIRE RESISTANCE DIRECTORYPHYSICAL PROPERTIESSpecSeal Elastomeric Sealant is designed primarily for the protection of construction joints. SpecSeal Elastomeric Sealant is a non-halogenated latex-based, highly elastomeric caulk designed to provide passive smoke and fire protection in construction joints. This material is also designed to restore sound attenuation properties to sound-rated ceilings and Elastomeric Sealant is engineered to adhere to virtually all construction surfaces and may be applied using standard caulking equipment or by troweling. SpecSeal Elastomeric Sealant dries to form a flexible shield against the propagation of fire. Its premium latex binder system is totally resistant to water and will not re-emulsify after drying. SpecSeal Elastomeric Sealant contains no inorganic fibers, asbestos, or applied to a wet film thickness of 1/4" ( mm) to 1/2" ( mm) over appropriate backing materials, SpecSeal Elastomeric Sealant has been successfully tested in one, two, three and four hour joints when tested in accordance with UL2079 (ASTM E1966). All tested systems have been cycled 500 times at total movement up to + 25%. Consult factory for individual system designs and application requirements. LIMITATIONS: Use product as per manufacturer s instructions. Use only in applications per the manufacturer s tested and published designs or per specific recommendations. End user must ultimately determine the suitability of the product and designs to his specific requirement and assumes responsibility for its use. STI Product Data Sheet ES Elastomeric Sealant FOD-5032 01/2012Table A: PRODUCT NAMESeries ESColorPale Blue or RedOdorMild LatexDensity10 Lb/Gal ( kg/L)Solids66% Content By Weight81%Solids Content By Temp.<185 F (85 C)Storage F (4 C) - 95 F (35 C)Flame Spread5*Smoke Development5*Movement 25%**Solvent ContentNoneDrying TimeTack Free 2 HoursADry through 5 to 7 daysASTC Rating62Shelf Life2 yrsVOC43 g/L * Tested to ASTM E84 (UL723) at 14% surface**500 Cycles per UL2079, AC30 (ICBO) and ASTM E1399ADependent on temperature and humidity2Technical Service FIG. 3: HEAD-OF-WALL JOINT - GYPSUM WALLBOARD WALL TO CONCRETE FLOORFIG. 4: HEAD-OF-WALL JOINT - GYPSUM WALLBOARD WALL CUT TO FIT CONTOURS OF STEEL DECKFIG. 5: HEAD-OF-WALL JOINT - GYPSUM WALLBOARD WALL TO CONCRETE OVER STEEL DECKGENERAL: Areas to be protected must be clean and free of oil, loose dirt, rust or scale. Recommended storage and application temperatures range between 40 F (4 C) and 95 F (35 C). When applying product at the lower end of the temperature range, warming the material to 70 F (21 C) will enhance drying characteristics. Drying time will vary according to prevailing temperature and humidity. Allow to thoroughly dry before exposure to appropriate manufacturer s drawing for system design requirements. Forming or packing materials may be required as an integral part of various system designs. See Table B for estimation is auto-bonding and may be applied in stages. DO NOT ATTEMPT TO THIN PRODUCT BY ADDING PRODUCT IS DESIGNED FOR PROFESSIONAL INSTALLATION ONLY. This sealant is designed to contract while drying. Proper joint design is critical to sealant performance. Avoid three point adhesion through the use of appropriate backing or bond-breaking materials. See Figure 2 for recommended joint designs. Consult ASTM C1193 Standard Guide for Use of Joint Sealants for additional guidelines concerning the proper application of sealant Product Data Sheet ES Elastomeric Sealant FOD-5032 01/2012SPECIFICATIONSThe fire protective sealant shall be a water-based, non-halogenated, elastomeric and shall contain no solvents, inorganic fibers, nor asbestos. The sealant shall dry to form a flexible, moisture resistant seal and shall adhere to all common construction surfaces. The sealant shall have demonstrated sound attentuation properties. The approved sealant shall be SpecSeal Elastomeric DIVISIONSDIV. 7 07 84 00 FirestoppingDIV. 7 07 84 43 Fire Resistant Joint SealantsMAINTENANCEInspection: Installations should be inspected periodically for subsequent damage. Following safety precautions listed in Precautionary Information and pertinent installation guidelines, remove coating in damaged areas down to undamaged material. Reapply fresh coating material to original coating thickness. UL System No. HW-D-0079Assembly Rating 1 & 2 Hr Movement Capabilities: 25% Joint Width: 3/4 Forming Material: In 1 hr walls, apply bond breaker tape to ceiling Depth: 5/8 depth on both System No. HW-D-0103Assembly Rating 1 & 2 Hr Movement Capabilities: 25% Joint Width: 3/4 Forming Material: In 1 hr walls, apply bond breaker tape to ceiling Depth: 1/2 depth on both System No. HW-D-0034Assembly Rating 1 & 2 Hr Movement Capabilities: 25% Joint Width: 1 Forming Material: Nom 4 pcf mineral wool to full Depth: 1/2 depth on both Service 6: HEAD-OF-WALL JOINT - MASONRY WALL TO CONCRETE OVER STEEL DECKUL System No. HW-D-0039Assembly Rating 2 HrMovement Capabilities: 25% Joint Width: 1 Forming Material: Nom 4 pcf mineral wool to full Depth: 1/4 depth on both 7: HEAD-OF-WALL JOINT - MASONRY WALL TO CONCRETE FLOORUL System No. HW-D-0041Assembly Rating 3 HrMovement Capabilities: Compress/Extend or 25% Joint Width: 1 or 3/4 (See System).Forming Material: Optional foam backer Depth: 1 or 1/2 (See System) on both 8: FLOOR-TO-FLOOR JOINT - CONCRETE FLOOR TO CONCRETE FLOORUL System No. FF-D-0005Assembly Rating 3 HrMovement Capabilities: Compress/ExtendNominal Joint Width: 1 Forming Material: Optional foam backer Depth: 1/2 top and 9: FLOOR-TO-WALL JOINT - CONCRETE FLOOR TO \CONCRETE WALLUL System No. FW-D-0005Assembly Rating 3 HrMovement Capabilities: Compress/ExtendNominal Joint Width: 1 Forming Material: Optional foam backer Depth: 1/2 top and 10: FLOOR-TO-FLOOR JOINT - CONCRETE FLOOR TO CONCRETE FLOORUL System No. FF-D-1008Assembly Rating 3 HrMovement Capabilities: 15% Compress/ExtendNominal Joint Width: 4 Forming Material: Nom 4 pcf mineral wool to 4 Depth: 1/2 depth of 11: FLOOR-TO-WALL JOINT - CONCRETE FLOOR TO CONCRETE WALLUL System No. FW-D-1007Assembly Rating 3 HrMovement Capabilities: 15% Compress/ExtendNominal Joint Width: 4 Forming Material: Nom 4 pcf mineral wool to 4 Depth: 1/2 depth of Product Data Sheet ES Elastomeric Sealant FOD-5032 01/20124Technical Service NOTICE: All statements, technical information, and recommendations contained herein are based upon testing believed to be reliable, but the accuracy and completeness thereof is not Technologies Inc. manufactures its goods in a manner to be free of defects. Should any defect occur in its goods (within one year), Specified Technologies Inc., upon prompt notification, will at its option, exchange or repair the goods or refund the purchase AND EXCLUSIONS: THIS WARRANTY IS IN LIEU OF ALL OTHER REPRESENTATIONS EXPRESSED OR IMPLIED (INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR USE) AND UNDER NO CIRCUMSTANCES SHALL SPECIFIED TECHNOLOGIES INC. BE RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL PROPERTY DAMAGE OR LOSSES. PRIOR TO USE, THE USER SHALL DETERMINE THE SUITABILITY OF THE PRODUCT FOR ITS INTENDED USE, AND THE USER ASSUMES ALL RISKS AND LIABILITY FOR SUBSEQUENT statement or recommendation not contained herein shall have any force or effect unless in an agreement signed by officers of seller and IN THE USA COPYRIGHT 2012 SPECIFIED TECHNOLOGIES OF NEW YORK MEA 290-98-MAVAILABILITYTECHNICAL SERVICEPRECAUTIONARY INFORMATIONSpecified Technologies Inc. provides toll free technical support to assist in product selection and appropriate installation design. UL Systems, Material Safety Data Sheets and other technical information is available at the Technical Library at Material Safety Data Sheet for additional information on the safe handling and disposal of this material. Wash areas of skin contact with soap and water. Avoid contact with eyes. Apply in areas with adequate ventilation. SpecSeal Elastomeric Sealant is available from authorized distributors nationwide. Consult factory for the names and locations of the nearest sales representatives or distributors. Table B: PRODUCT ESTIMATION INFORMATION (Construction Joints)JOINTPER 1/4 INSTALLED DEPTHPER 1/2 INSTALLED DEPTH PER 1 INSTALLED DEPTHWIDTHCU IN/FTFT/GALGAL/100 FTCU IN/FTFT/GALGAL/100 FT CU IN/FTFT/GALGAL/100 INFORMATIONSpecSeal Elastomeric Sealant is available in caulk tubes, sausages and No. Description ES100 oz. Tube (300 ml) oz. Tube (858 ml) 52 20 oz. Sausage (592 ml) 36 cu. 5 Gal. Pail ( liters) 1,155 Product Data Sheet ES Elastomeric Sealant FOD-5032 01/2012210 Evans Way, Somerville NJ 08876 USA Phone: Fax: Service Series SSS Sealant is a latex based, high solids firestop compound. This material, when properly installed, will effectively seal penetration openings against the spread of fire, smoke, toxic gasses and Series SSS Sealant features STI s patented and proprietary two-stage intumescent technology. When exposed to high temperatures or fire, this material expands aggressively in a highly directionalized fashion to quickly close off voids left by the burning or melting of combustible materials. SpecSeal Series SSS Sealant s unique multi-viscosity formula yields a single grade that has excellent caulking properties as well as high build properties on vertical or overhead surfaces. This single grade may be pumped, caulked (standard cartridge or bulk loaded), knifed or troweled. In addition, SpecSeal Series SSS Sealant does not contain PCB s or Series SSS Sealant is storage stable (when stored according to the manufacturer s recommendations) and will not separate nor shrink when dried. SpecSeal Series SSS Sealant will adhere to all common construction and penetrant materials and contains no solvents that might adversely effect plastic pipes or cable SSS INTUMESCENT SEALANTSTI Product Data Sheet Series SSS Intumescent Sealant FOD-5001 05/2010PRODUCT DATA SHEETAPPLICATIONSPRODUCT DESCRIPTIONSpecSeal Series SSS Sealant is used to seal through-penetrations as well as construction gaps and blank openings. SpecSeal Series SSS has been tested for use with metallic penetrants up to 30" (762 mm) trade size. This product is also used with other SpecSeal Products such as SpecSeal Firestop Collars and Wrap Table A for a summary application list. Water-Based Easy installation, cleanup, and disposal. Two-Stage Intumescence Extremely fast and directionalized expansion. Endothermic Fillers Absorb heat & release water. High Solids Formula No shrinkage! Sandable & Paintable (when dry) Water-Resistant Will not re-emulsify when dry! Safe Safe for contact with plastics. Red Color Easy identification and inspection. Multi Viscosity Grade Excellent caulking properties along with high build capabilities. Excellent Smoke Seal FEATURE BENEFITPERFORMANCESpecSeal Series SSS Sealant is the basis for systems that meet the exacting criteria of ASTM E814 (UL1479) as well as the time-temperature requirements of ASTM E119 (UL263). Systems have been tested for all common forms of construction and most common penetrants with ratings up to 4 hours. STI firestop systems are designed to maximize the fire resistance of the seal by not only sealing off the spread of fire and hot gasses but also by minimizing the amount of heat conducted through the assembly. Thus all systems have been designed to provide T Ratings capable of matching the rating of the wall or floor assembly (where possible) when tested without , VOID OR CAVITY MATERIALS FOR USE IN JOINT SYSTEMS AND THROUGH-PENETRATION FIRESTOP SYSTEMS. SEE UL DIRECTORY OF PRODUCTS CERTIFIED FOR CANADA AND UL FIRE RESISTANCE DIRECTORY. PropertiesSeries SSSColorRedOdorMild lb/gal ( kg/L)Solids Content80% 2% Service Temperature-10 F (-23 C) - 185 F (85 C) Storage Temperature40 F (4 C) - 95 F (35 C) Flame Spread0*Smoke Developed*10** Tested to ASTM E84 (UL723) at 14% surface coverage (modified test for sealants and caulks) PropertiesSeries SSSSTC Rating (ASTM E90/ASTM C919)62VOC Content (EPA Method 24/ASTM D3960) lbs/gal ( g/L)Shelf Life2 yrsExpansion Begins230 F (110 C) 1st Stage350 F (177 C) 2nd StageExpansion Range230 F to > 1,000 F(110 C to > 538 C)Volume Expansion> 500% Free ExpansionPHYSICAL PROPERTIES2Technical Service below and on the following page are just a few of the most common applications for SpecSeal Series SSS Sealant. Consult the Technical Library at for over 200 avail-able designs utilizing this A: APPLICATIONSTESTED AND CLASSIFIED FOR FIRE RESISTANCE Metallic Pipes including steel, iron, or copper pipe and tubing through all common constructions. Nonmetallic Pipes, Conduits &Tubing including PVC, CPVC, PVDF, PEX, PEX-AL-PEX, ABS, PB through all common constructions. Cable, Cable Trays & Bus Duct HVAC Ductwork Insulated Pipes Multi-Service Penetrations including AC line sets, electrical, telephone, or TV service entrance and interior penetrations. Complete Wood Floor firestopping package for electrical, plumbing, HVAC, TV and 1: METALLIC PIPE PENETRATIONS - CONCRETE/MASONRY FLOORS & WALLSUL SYSTEM C-AJ-1079F Rating: 4 Hr T Rating: 0Steel or Iron Pipe: 24", Copper Pipe 6"Annulus: Point Contact to 4" S alant Depth: 1/2" Forming Mate-rial: Nom 4 pcf Mineral WoolThickness: 1-1/2" for 6" Steel or Iron Pipe3" for 4" Copper or 6" Iron or Steel PipeUL SYSTEM C-AJ-1217F Rating: 4 Hr T Rating: 0Steel or Iron Pipe: 30", Copper Pipe 6"Annulus: Point Contact to 2" S alant Depth: 1/2"Forming Material: Nom 4 pcf Mineral WoolTightly Packed to a 3" 2: INSULATED METALLIC PIPE PENETRATIONS - CONCRETE/MASONRY FLOORS & WALLSUL SYSTEM C-AJ-5087F Rating: 2 Hr T Rating: 1Steel or Iron Pipe: 24"Insulated with 2" Thick Fiber Glass or Mineral Wool Pipe InsulationAnnulus: 1/2" to 1-1/2" Sealant Depth: 1/2" Forming Material: Nom 4 pcf Mineral Wool Tightly Packed to a 4" firestopping sealant shall be a one-part, two-stage intumescent latex compound. The sealant when exposed to high heat or flame shall be capable of expanding a minimum of 8 times. Range of continuing expansion shall be from 230 F to >1,000 F (110 C to > 538 C). The sealant shall be thixotropic and shall be capable of caulking or troweling onto vertical surfaces or overhead. The sealant shall be UL Classified and/or FM Systems Approved and tested to the requirements of ASTM E814 (UL1479).SPECIFIED DIVISIONSDIV. 7 07840 Through-Penetration FirestoppingDIV. 13 13900 Special Construction Fire Suppression & Supervisory SystemsDIV. 15 15250 Mechanical Insulation Fire ProtectionDIV. 16 16050 Basic Electrical Materials & MethodsSPECIFICATIONSSTI Product Data Sheet Series SSS Intumescent Sealant FOD-5001 05/2010Pipe Size Diameter of Opening (in.) 10 12 14 26Trade Pipe Size " 1" " 2" " 3" " 4" 6" 8" 10" 12" 24" IMPORTANT NOTE: This table is for estimation purposes only. Consult UL Fire Resistance Directory or STI Product & Application Guide for specific installation requirements and limitationsMetric Estimation Table available upon request. SEALANT REQUIREMENTS IN CUBIC INCHES PER 1/4 INCH OF INSTALLED DEPTH**Different Sealant Depth? 1/2" Multiply by 2 5/8" Multiply by 1" Multiply by 4 1-1/4" Multiply by 53Technical Service 5: BARE & INSULATED METALLIC PIPE PENETRATIONS - RATED GYPSUM WALLBOARD ASSEMBLIESUL SYSTEM W-L-1049F Rating: 2 hr T Rating: 0 hrSteel or Iron Pipe: 24", Copper Pipe: 6"Annulus: Point Contact to 2"Sealant Depth: 5/8" with 3/8" CrownUL SYSTEM W-L-5014 F Rating: 1 & 2 Hr T Rating: 1 & 2 hrSteel or Iron Pipe: 12", Copper Pipe: 4"Insulated with 2" Thick Fiber Glass or Mineral Wool Pipe InsulationAnnulus: 0" to 1-1/4"Sealant Depth: 5/8" with 3/8" CrownUL SYSTEM W-L-5051F Rating: 1 & 2 Hr T Rating: 3/4, 1, 1-1/2 & 2 HrSteel or Iron Pipe: 16", Copper Pipe: 6 Foam Glass Pipe Insulation: 1 to 3 Thick 12" Wide " Thick Metal Jacket Wrapped Around Insulation and Secured with Metal Banding as Shown Annulus: 0 to 1-1/2" Sealant Depth: 5/8" INSTALLATION INSTRUCTIONSGeneral: Areas to be protected must be clean and free of oil, loose dirt, rust or scale. Installation temperatures must be between 35 F and 100 F (2 C and 38 C). Allow product to dry a minimum of 24 hours before exposure to Selection: Selection of an appropriate firestop system design is critical to the fire protection process. Space limitations preclude highly detailed information pertaining to individual application systems. Please consult the STI Product & Application Guide as well as the UL Fire Resistance Directory for additional : Some installations may require forming as either an integral part of the system or as an option to facilitate installation. In systems where forming is required, mineral wool batts (min. nom. 4 lb/cu. ft (64 kg/m3) density) are recommended. Some gypsum wallboard systems utilize fiberglass. Cut forming material over-size to allow for tight packing. Position forming material to allow for the proper depth of fill Material: SpecSeal Series SSS Sealant may be installed by caulking using a standard caulking gun or from bulk containers using a bulk loading caulk gun, or by manually troweling using a mason s trowel or putty knife. If the sealant tends to pull back from a surface, clean the surface with a damp rag or sponge and reapply. Work sealant into all areas exercising care to eliminate voids or seams. The surface of the sealant can be smoothed using a putty knife dipped in water. Adding water to the sealant itself is not recommended. Sealant (when dry) may be sanded and painted using most non-solvent based paints. In gypsum wallboard penetrations, crown sealant 1/4" (6 mm) from penetrant to wallboard surface at a point approximately 1/2" (13 mm) or more from opening. Sealant (ehen dry) may be painted using most non-solvent based paints,Smoke Sealing: In some applications including firestop collars, SpecSeal Series SSS Sealant is recommended as a smoke seal. It is suggested in these application that the sealant be applied to both sides of walls. In floor applications, a sealing bead is suggested top and 3: ELECTRICAL, DATA OR COMMUNICATIONS PENETRATIONS - RATED GYPSUM WALLBOARD ASSEMBLIESUL SYSTEM W-L-3076F Rating: 1 or 2 Hr T Rating: 0 hrUp to 4" Cable BundleCentered in 4 - 1/2" OpeningSealant Depth: 5/8" with 1/4" CrownUL SYSTEM W-L-2093F Rating: 1 or 2 Hr T Rating: 1, 1-1/2 Hr 2" Rigid PVC, ENMT, or Optical Fiber Raceway. 1-1/4" PVDF Optical Fiber Depth: 5/8" with 1/4" CrownFig. 4: ELECTRICAL PENETRATIONS - CONCRETE/MASONRY FLOORS & WALLSUL SYSTEM C-AJ-3154F Rating: 1, 2, 3 & 4 Hr T Rating: 0, 1/2, & 2 3/4 HrOptional Sleeve-PVC or SteelElectrical, Telephone or Data CablesAnnulus: 0" to 2"Sealant Depth: 1/2"Forming Materials: Nom 4 pcf Mineral Wool Sealant Depth: 1/2 for 1, 2, 3 Hr; 1 for 4 HrUL SYSTEM C-AJ-6008F Rating: 3 Hr T Rating: 0 HrAluminum or Copper Bus Duct 5,000 AmpSteel Cover PlateSealant Depth: 1/2"Forming Materials: Nom 4 pcf Mineral WoolTightly Packed to a depth of 1-1/2"STI Product Data Sheet Series SSS Intumescent Sealant FOD-5001 05/20104Technical Service : Installations should be inspected periodically for subsequent damage. Any damage should be repaired using SpecSeal products per the original approved : When adding or removing penetrants, care should be taken to minimize damage to the seal. Reseal using SpecSeal products per the approved design. NOTE: New penetrants of a different nature than the original design may require a totally new firestop design or extensive modifications to the existing design. Reseal all openings as per the requirements of the modified Technologies Inc. provides toll free technical support to assist in product selection and appropriate installation design. UL Systems, Material Safety Data Sheets and other technical information is available through the Technical Library at Material Safety Data Sheet for additional information on the safe handling and disposal of this material. Wash areas of skin contact with soap and water. Avoid contact with eyes. SEALANT IS CONDUCTIVE UNTIL Series SSS Sealant is available from authorized STI distributors. Consult factory or website for the names and locations of the nearest sales representatives or distributors. AVAILABILITYPRECAUTIONARY INFORMATIONTECHNICAL SERVICEMAINTENANCEIMPORTANT NOTICE: All statements, technical information, and recommendations contained herein are based upon testing believed to be reliable, but the accuracy and completeness thereof is not Technologies Inc. manufactures its goods in a manner to be free of defects. Should any defect occur in its goods (within one year), Specified Technologies Inc., upon prompt notification, will at its option, exchange or repair the goods or refund the purchase AND EXCLUSIONS: THIS WARRANTY IS IN LIEU OF ALL OTHER REPRESENTATIONS EXPRESSED OR IMPLIED (INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR USE) AND UNDER NO CIRCUMSTANCES SHALL SPECIFIED TECHNOLOGIES INC. BE RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL PROPERTY DAMAGE OR LOSSES. PRIOR TO USE, THE USER SHALL DETERMINE THE SUITABILITY OF THE PRODUCT FOR ITS INTENDED USE, AND THE USER ASSUMES ALL RISKS AND LIABILITY FOR SUBSEQUENT statement or recommendation not contained herein shall have any force or effect unless in an agreement signed by officers of seller and IN THE USA COPYRIGHT 2010 SPECIFIED TECHNOLOGIES Technologies Inc. 210 Evans Way, Somerville, NJ 08876 USA Phone: Fax: oz. Tube (300 ml) oz. Tube (858 ml) 52 cu. oz. Sausage (592 ml) 36 cu. Gal. Pail ( liters) 462 Gal. Pail ( liters) 1,155 Product Data Sheet Series SSS Intumescent Sealant FOD-5001 05/2010INSTALLATION INSTRUCTIONS LIMITATIONS: SpecSeal Series SSS Sealant is water-based and cures through the evaporation of water. Low temperatures as well as high humidity may retard drying. Non-porous or impermeable backing materials, plates, or coatings may retard the drying process. Do not paint or seal in any way that prevents contact with air until sealant has dried through completely. This product has been designed to be safe with plastics and has been used extensively and successfully with a variety of different types of plastic pipes, tubes, and plastic cable insulations. Variations in these materials however, make it impos-sible to guarantee compatibility. STI strongly recommends that the user consult with the manufacturer of the pipe, tubing, or cable in question regarding any known sensitivities or potential restrictions before applying this OF NEW YORK MEA 28-92-M

Related search queries