Example: air traffic controller

HB 100 MICROWAVE SENSOR MODULE HB 100 …

HB 100 MICROWAVE SENSOR MODULE • Low current consumption • CW or Pulse operation • Flat profile • Long detection range HB100 Miniature Microwave Motion Sensor is a X-Band Bi-Static

Tags:

  Sensors, Motion, Module, Microwave, Hb 100 microwave sensor module

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Text of HB 100 MICROWAVE SENSOR MODULE HB 100 …

HB 100 MICROWAVE SENSOR MODULE Low current consumption CW or Pulse operation Flat profile Long detection range HB100 Miniature Microwave Motion Sensor is a X-Band Bi-StaticDoppler transceiver module. Its built-in Dielectric ResonatorOscillator (DRO) and a pair of Microstrip patch antenna array,make it ideal for OEM usage in motion detection equipment. This module is ideally suitable for false alarms reduction in intruderdetectors when work together with Passive Infrared (PIR) sensor. Itcan also be used for auto-door opening and vehicle speedmeasurement. Microwave-PIR motion detector Speed measurement Lighting control Applications Features Description Microwave Motion Sensor Module HB 100 Microwave Sensor Module CERT. NO. : 94-1-0033 SS ISO 9001 : 2000 Block diagram and connection 0306090120150180210240270300330-30-24-24 -18-18-12-12-6-6030609012015018021024027 0300330-36-30-30-24-24-18-18-12-12-6-6 Antenna Beam Pattern Azimuth Elevation HB 100 MICROWAVE SENSOR MODULE Azimuth Elevation Unless noted otherwise, the specifications are measured with +5VDC, CW operation, 12 k load at ambient temperature of +25 C. Parameter Notes Min Typ. Max Units Frequency Setting 1 GHz Radiated Power (EIRP) 1 12 15 20 dBm Spurious Emission 1 dBm Settling Time 3 6 Sec Received Signal Strength 2 200 Vp-p Noise 3 5 Vrms Antenna Beam-width (3 dB) - Azimuth 80 Antenna Beam-width (3 dB) - Elevation 40 Supply Voltage VDC Current Consumption 30 40 mA Pulse Repetition Frequency 4 2 KHz Pulse Width 4 10 Sec Operating Temperature -15 55 C Weight 8 gm Note 1: The radiated emissions of HB100 is designed to meet the requirements of Federal Communications Commission (FCC) rules, Part 15, Section (use within a building or to open building door) Note 2: The Received Signal Strength (RSS) is measured at the total 2 ways path loss of 93dB. Note 3: The noise voltages are measured from 10 Hz to 100 Hz at the output port, inside an Anechoic chamber. Note 4: Pulse operation. Note 5: The design, manufacturing process and specifications of this device are subjected to change without prior notice. Note 6: CAUTION: ELECTROSTATIC SENSITIVE DEVICE. Observe precautions for handling and storage. Technical Specifications Outline diagram (All dimensions in mm) VER Elevation A company of Singapore Technologies Engineering

Related search queries