2-HOUR FIRE-RATED FAS - ECS - Electrical Cable …

Qualified to the toughest Canadian Standards, Lifeline ™ FAS is 2-hour fire rated to ULC S-139-00 and CSA type FAS certified without the need for extra barrier ...

Tags:

  Lifeline, Fire, Hours, Trades, 2 hour fire rated

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Text of 2-HOUR FIRE-RATED FAS - ECS - Electrical Cable …

Qualified to the toughest Canadian Standards, Lifeline FAS is 2-hour fire rated to ULC S-139-00 and CSA type FAS certified without the need for extra barrier tapes, metal sheaths or special installation procedures. Designed to meet the fire rating requirements of the National Building Code of Canada, the functional requirements of the National Fire Code of Canada and the installation requirements of the Standard for the Installation of Fire Alarm Systems. Beyond the obvious economical advantages as a fire rated system, Lifeline FAS offers a complete product line, circuit protection to 150 volts, standard installation and flexibility in a LSHF construction. Low capacitance and availability in long lengths improves system performance and reduces waste from unusable cable lengths. Call your LIFELINE friend at 800-333-4248 ext. 2600 Or visit us at BIW Cable Systems, Inc. Draka Comteq USA, Inc. Draka Elevator Products Tamaqua Cable Products Tel Tel Fax 2-HOUR FIRE-RATED FAS Fire Alarm Cable DESCRIPTION Lifeline FAS is a 2-hour fire rated fire alarm cable using ceramified silicone technology to provide a flexible cable with the highest level of installed reliability. Designed for use in critical circuits that may require operation in the presence of fire and water, Lifeline FAS can be used in fire alarm systems for detection, notification, signaling, communications or in any system where orderly egress or safe shutdown is essential. LIFELINE FAS CSA CERTIFIED FAS FIRE ALARM CABLE C-UL CLASSIFIED 2-HOUR FIRE RATING PER ULC S-139 WITH HOSE STREAM AT 150 VOLTS FEATURES & BENEFITS Canadian Approved 2-Hour Fire Rating CSA Certified Type FAS for use at Maximum Canadian Code Ampacity 300 Volt Cable/150 Volt Utilization Complete Product Line, Sizes and Types Installs in Common 1/2 (or larger) Conduit Low Smoke, Halogen Free (LSHF) Construction Savings from Long Length Availability 2 Inch Pair Lay Length PERFORMANCE SPECIFICATIONS C-UL 2-Hour Fire Rating per ULC S-139-00 at 150 Volts and hose stream CSA Certified Type FAS to CSA STD. NO. 208-03 Complies with fire rated cable of CAN/ULC-S524-01 Standard for the Installation of Fire Alarm Systems For installation per CSA Canadian Elec-trical Code, Part 1, Safety Standard for Electrical Installations Additionally, Lifeline FAS is qualified to UL 2196 Standard for Tests for Fire Resistive Cables and is listed as Electrical Circuit Protec-tive System (FHIT) #24 of the UL Fire Resistance Directory. MAINTAIN CIRCUIT INTEGRITY AND PHYSICAL PROTECTION WITH A SIMPLE, IN CONDUIT SOLUTION LifelineTM Part Number Copper AWG Size STRAND Number of Conductors Overall Diameter In. (mm) Weight Lbs/Mft (kg/km) Nominal Capacitance pf/ft (pf/m) DC Resistance Ohms/Mft FAS-2C/18NS 18-solid 2 ( ) 53 (79) 15 (48) FAS-4C/18NS 18-solid 4 ( ) 76 (113) 15 (48) FAS-6C/18NS 18-solid 6 ( ) 104 (155) 15 (48) FAS-8C/18NS 18-solid 8 ( ) 136 (202) 15 (48) FAS-2C/16NS 16-solid 2 ( ) 62 (92) 17 (56) FAS-4C/16NS 16-solid 4 ( ) 94 (140) 17 (56) FAS-2C/14NS 14 -7 str 2 ( ) 80 (119) 19 (62) FAS-4C/14NS 14 -7 str 4 ( ) 125 (186) 19 (62) FAS-2C/12NS 12 -7 str 2 ( ) 101 (150) 21 (69) FAS-4C/12NS 12 -7 str 4 ( ) 168 (250) 21 (69) Unshielded - CSA type FAS and 2-Hour Fire Rated per ULC S139-00 at 150 Volts For more information, call your LIFELINETM friend at 1-800-333-4248 ext. 2600 Lifeline_ fas_ Feb_04 LifelineTM Part Number Copper AWG Size STRAND Number of Conductors Overall Diameter In. (mm) Weight Lbs/Mft (kg/km) Nominal Capacitance pf/ft (pf/m) DC Resistance Ohms/Mft FAS-2C/18OS 18-solid 2 ( ) 57 (85) 26 (85) FAS-4C/18OS 18-solid 4 ( ) 81 (121) 26 (85) FAS-6C/18OS 18-solid 6 ( ) 110 (164) 26 (85) FAS-8C/18OS 18-solid 8 ( ) 142 (211) 26 (85) FAS-2C/16OS 16-solid 2 ( ) 66 (98) 30 (98) FAS-4C/16OS 16-solid 4 ( ) 99 (147) 30 (98) FAS-2C/14OS 14 -7 str 2 ( ) 85 (126) 36 (118) FAS-4C/14OS 14 -7 str 4 ( ) 130 (193) 36 (118) FAS-2C/12OS 12 -7 str 2 ( ) 106 (158) 42 (138) FAS-4C/12OS 12 -7 str 4 ( ) 173 (257) 42 (138) Shielded Overall - CSA type FAS and 2-Hour Fire Rated per ULC S139-00 at 150 Volts LIFELINETM FAS JACKET PRINT LEGEND (typical) DRAKA USA 2/C 16 AWG OS LIFELINE FAS FIRE ALARM CABLE (CSA) TYPE FAS FT1 LL36970 c(UL) 2 HOUR CIR ULC S-139 (150 VOLTS) HOSE STREAM R 19359

Related search queries